Electrical Specifications (Standard Type); Environmental Specifications; Name And Description Of Each Part; Components - GASTRON GTD-1000T Series Instruction Manual

Gas & flame detection system
Table of Contents

Advertisement

GTD-1000Tx(M)
Instruction Manual

3.3. Electrical Specifications (Standard Type)

ITEMS
Input Voltage(Standard)
※ Customer supplied PSU must meet
requirements IEC1010-1 and CE
Marking requirements.
Ripple maximum allowed:
Wattage
Analog output Current
Analog output current ripple & noise max
Power
Wiring requirement
Analog
Analog
Cable Connection Length
RS-485
EMC Protection:

3.4. Environmental Specifications

ITEMS
Transmitter
Operation Temperature
Sensor
Transmitter
Storage Temperature
Sensor
Transmitter
Operation Humidity
Sensor
Pressure Range
Max. air velocity
3. Specification
SPECIFICATION
Absolute min:
18V
Nominal:
24V
Absolute max:
31V
1V pk-pk
Max. wattage:
3.6W @+24 VDC
Max. current:
150mA @+24 VDC
0-20mA(500 ohms max load)
All readings ± 0.2mA
Measured-value signal:
4mA(Zero) to 20mA(Full Scale)
Fault:
0mA
0-100% LEL:
4mA - 20mA
100-109%LEL:
20mA - 21.4mA
Over 110% LEL:
22mA
Maintenance:
3mA
±20uA
CVVS or CVVSB with shield
CVVS or CVVSB with shield
2500m
1000m
Complies with EN50270
SPECIFICATION
-20 to 50 ℃
Refer to Sensor Specification
-20 to 50 ℃
Refer to Sensor Specification
5 to 99% RH (Non-condensing)
Refer to Sensor Specification
90 to 110KPa
6m/s

4. Name and Description of Each Part

4.1. Components

[Figure 2. GTD-1000Tx(M) Components]
NO
NAME
1
Housing Body
Protects PCB Board built in Sensor and Housing from external environmental change and shock.
It is assembled with detector housing body and protects PCB Board built in Sensor and Housing from
2
Housing Cover
external environmental change and shock
It is a site that detects actual gas leak. It converts the amount of gas leak into electrical signal and
3
Sensor
transmits to the Main PCB.
It must be grounded to inside of detector for protection from external noise or strong electric field.
4
Internal Ground
- Use a conductor that is 4 mm or longer when coupling ground line.
It must be grounded to outside of detector for protection from external noise or strong electric field.
5
External Earth Ground
- Use a conductor that is 4 mm or longer when coupling ground line.
It is supplied for inlet of power supply and measurement output signal for the detector during
6
Conduit Connection
installation. For cable inlet, PF or NPT 1/2", 3/4" are prepared.
Amplifies fine outputs generated from Sensor Element to transmit a converted output in 4~20 mA
7
Main PCB
DC standard. It sends data to display part.
8
Mount Hole
Hole to fix the gas detector on external wall or other installation sites.
www.gastron.com
08_09
DESCRIPTIONS