Error Codes - Abilica XC 2700 MILL V4 User Manual

Table of Contents

Advertisement

Error codes

Error Code
Description
E1
Communication
error between
Inverter and console
E2
Inverter too hot
E3
Low input voltage
E4
Incline adjustment
E5
Overvoltage,
Inverter
E7
Overload protection 1. Switch off for over 20 seconds and switch on again.
E9
Incline error
Er
Inverter error
— —
Safety key not
detected
No display on
computer
Solutions
1. Check if computer is connected to inverter with correct wires, check connector,
check if wire is damaged, or unplug and re-connect
2. Replace inverter and test
3. Replace computer and test
1. Switch off for over 20 seconds and switch on again.
2. Check if the fan and heat sink are clean or if the fan is working.
3. Replace inverter.
1. Switch off for over 20 seconds and switch on again.
2. Check if the input voltage low.
3. Replace inverter.
1.
Check incline motor sensor wire if connect well, re-plug in.
2.
Check incline motor AC cable if connect correct, the incline AC cable is
connect correct to follow the controller mark.
3.
Check if the cable of motor is damage.
4.
Replace cable or incline motor, then press the adjustment button to running
again.
1. Skru av i 20 sekunder, og skru på igjen.
2. Forsikre deg om at valsene beveger seg uhindret. Forsikre deg om at løpebåndet
og plattformen er tilstrekkelig smurt, er moderat stramt og ikke har for mye
slitasje.
3. Bytt omformer.
2. Check if roller bearings are stuffed and not rotating freely inside front and rear
rollers, check if running belt and running deck are well lubricated without
excessive wear and tear, check belt tension is moderate.
3. Replace inverter.
1.
Check the incline sensor is well contact or not.
2.
Replace inverter.
3.
Replace incline motor
1.
Switch off for over 20 seconds and switch on again.
2.
Check the connecting line is well or not.
3.
Replace inverter.
1. Check if safety key switch works, connecting wire works, or magnet inside
works.
2. Safety key is not connected correctly.
3. Safety key is damaged, check and replace.
1. Check if power cable is connected to machine or change to another power
outlet. If power switch is in position, test it by switch ON/OFF. If the power switch
is burned out, replace one and make sure there's power to machine
2. Check cable connection between computer and inverter.
3. Replace inverter or computer.
36

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents