User Tasks
2.3 Configuring the WinCC flexible Project
Changing the WinCC flexible runtime settings
To change the runtime settings for a new Windows user follow these steps:
1. Log on to the Panel PC with the new Windows user name and password.
2. Select the Start > Programs > Startup menu command to modify the RT Loader settings.
3. In the Directories section, change the locations for "Configuration file" and "Configuration
backup file" to D:\ drive locations, but do not modify the "Autostart application" location:
Figure 2-8
4. Click OK. Your runtime settings are now configured to persist after a reboot.
In addition, the default settings for recipes and archives also specify file locations on the C:\
drive. If you use these options, change these default settings to specify file locations on the
44
WinCC flexible 2007 RT Loader Settings
NOTICE
If you ever restore your Microbox 427B-HMI/RTX or Panel PC 477B-HMI/ -HMI/RTX
from a custom system image CD (Page 48) or from the Restore CD (Page 50) and
subsequently create a new Windows user, you must again change the runtime settings
to D:\ drive locations.
Microbox 427B-RTX/ -HMI/RTX and Panel PC 477B-HMI/ -HMI/RTX
Manual, 12/2007, A5E01217837-01