Other Emergencies

Power Lever Linkage Failure

1. Power Lever Movement ................................................................... VERIFY
2. Power ......................................................................................... SET IF ABLE
3. Flaps .....................................................................................SET IF NEEDED
4. Mixture ................................AS REQUIRED (FULL RICH TO CUTOFF)
5. Land as soon as possible.
If the Power Lever linkage fails in flight, the engine will not
respond to power lever control movements. Use power available
and flaps as required to safely land the airplane.
If the power lever is stuck at or near the full power position,
proceed to a suitable airfield. Fly a forced landing pattern. With
landing assured, shut down engine by moving mixture control full
aft to CUTOFF. If power is needed again, return mixture control
to full RICH and regain safe pattern parameters or go-around. If
airspeed cannot be controlled, shut engine down and perform the
Forced Landings
stop and complete the
If the power lever is stuck at or near the idle position and straight
and level flight cannot be maintained, establish glide to a suitable
landing surface. Fly a forced landing pattern.

Emergency Engine Shutdown On Ground

1. Power Lever ............................................................................................ IDLE
2. Fuel Pump (if used) ................................................................................. OFF
3. Mixture............................................................................................. CUTOFF
4. Fuel Selector.............................................................................................. OFF
5. Ignition Switch ......................................................................................... OFF
6. BAT 1, BAT 2, ALT 1, and ALT 2 Switches .........................................OFF
P/N 13772-006
Reissue A
Procedure Complete
• N
OTE
Checklist. After landing, bring the airplane to a
Emergency Engine Shutdown On Ground
Checklist.
Procedure Complete
S
3: E
ECTION
MERGENCY
O
P
ROCEDURES
E
THER
MERGENCIES
3-39

Advertisement

Table of Contents
loading

Table of Contents