Other Conditions

Aborted Takeoff

1. Power Lever ............................................................................................ IDLE
2. Brakes .................................................................................... AS REQUIRED
Use as much of the remaining runway as needed to safely bring the
airplane to a stop or to slow the airplane sufficiently to turn off
For maximum brake effectiveness, retract flaps, hold control yoke
full back, and bring the airplane to a stop by smooth, even applica-
After a high-speed aborted takeoff, brake temperatures will be
elevated. Subsequent aborted takeoffs or other high-energy use of
the brakes may cause brake overheat, failure and possibly even fire.
A 25-minute cooling time is recommended following high-energy
use of the brake system before attempting to conduct operations
that may require further high-energy braking. Brake temperature
indicator should be inspected prior to flight following a
high-energy brake event. Refer to Section 4,

PARK BRAKE Caution

Parking Brake Engaged Annunciation
1. Parking Brake ................................................................................. RELEASE
2. Monitor CAS for BRAKE TEMP Caution. Stop aircraft and allow the
brakes to cool if necessary.
P/N 13772-006
Reissue A
Procedure Complete
• N
OTE
runway.
• CAUTION •
tion of the brakes.
Checklist for additional detail.
PARK BRAKE
Procedure Complete
• N
OTE
Parking brake is set.