S
3A: A
ECTION
BNORMAL
I
A
NTEGRATED
VIONICS
ALT 2 Caution (Failure)
Low Alternator 2 Output
1. ALT 2 Circuit Breaker ................................................... CHECK AND SET
2. ALT 2 Switch....................................................................................... CYCLE
◆
If alternator does not reset:
a. ALT 2 Switch ......................................................................................OFF
b. Continue Flight, avoiding IMC or night flight as able (reduced power
redundancy).
Alternator 2 output is low, indicative of alternator failure. Isolated
Alt 2 failure will not typically be associated with any other unusual
indications, cautions or warnings (Alt 1 will pick up all loads).
Integrated Avionics System
AVIONICS OFF Caution
Avionics Switch Off
1. AVIONICS Switch ...................................................... ON, AS REQUIRED
3A-14
P
ROCEDURES
S
YSTEM
Procedure Complete
• N
AVIONICS OFF
Procedure Complete
• N
The AVIONICS switch is off.
ALT 2
•
OTE
•
OTE
C
D
IRRUS
ESIGN
SR22
P/N 13772-006