Vacuum switch
Hide thumbs Also See for VPEV-1/8-M12:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 13
VPEV-1/8-M12
S
Please comply with national and local safety laws and regulations.
S
Remove all packaging except for the adhesive labels on the compressed air
connections (danger of dirt entering).
The packaging can be recycled (except for oiled paper = waste).
S
Unauthorized product modification is not permitted.
S
Please observe the warnings and instructions on the product and in these op-
erating instructions.
4
Fitting
Mechanical components
If neccessary:
S
Fasten the VPEV-... with two M5 screws in the through holes 2.
Pneumatic components
S
Connect the VPEV-... with a threaded connector (e.g. type QS-..., CK-....) to the
vacuum connection G 1/8 (tightening torque max. 20 Nm).
If the plug screw 8 is repositioned in the
vacuum connection, the VPEV-... can be
used as a pressure switch.