■Creating and storing a script file
Create a script file that automatically downloads the execution module at the start of the C Controller module.
Operating procedure
1.
Open a text file and describe a script file that downloads a user program and generates a task, as shown below.
The "R12_SampleTask"
function is generated under
the default task name (t1).
2.
Name the file as "STARTUP.CMD" and save the file.
3.
Copy the created script file to the program memory in the C Controller module.
ftp://192.168.3.3/0
The script file has been created and stored.
A user program and a script file can be stored on the SD memory card as well.
When a script file is stored in both the program memory and the SD memory card, one in the SD memory card
is started by priority.
2 USING C CONTROLLER MODULE
50
2.5 Programming
The "R12_SampleProject.out"
file is loaded from the
program memory '0'.