Power Frequency Magnetic Field Immunity Tests; Test Record; Test Setup; Operating Condition - AOpen CRW1232 PRO Manual

Hide thumbs Also See for CRW1232 PRO:
Table of Contents

Advertisement

CE TEST REPORT

14. Power Frequency Magnetic Field immunity tests

Pass
performance Criteria :
??
Basic Standard
??
Generic Standard
??
Input Voltage, Frequency
??
Temperature
??
Relative Humidity
??
Test Date
??

14.1 TEST RECORD

Power Frequency
Magnetic Field
50Hz, 1A/m
50Hz, 1A/m
50Hz, 1A/m

14.2 TEST SETUP

14.3 OPERATING CONDITION

Full system
Test Engineer :
ROXY CHOU
SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255
A
:
EN 61000-4-8 ( 1993 )
:
EN 55 024 :1998
:
AC 230V, 50Hz
:
19 ° C
:
51 %
:
Feb. 16, 2001
Testing
duration
1.0 Min
1.0 Min
1.0 Min
AMP
Coil
Orientation
X-axis
Y-axis
Z-axis
EUT
Report No. : C121401
Results
Remark
Pass
Pass
Pass
Coil
0.8m
Page Number
: 53 of 62
Issued Date
: Feb. 21, 2001
Normal
Normal
Normal