CE TEST REPORT
European Standard EN 55022:1998 Class B
EN61000-3-2:1995/A12:1996/A13:1997/A1:1998/A2:1998,
EN 61000-3-3:1995/A1:1998 and EN 55024:1998
( EN61000-4-2:1995, EN61000-4-3:1996, EN61000-4-4:1995,
EN61000-4-5:1995, EN61000-4-6:1996, EN61000-4-8:1993,
Equipment : CD-RW
Model No.
Applicant
? ?
The test result refers exclusively to the test presented test model / sample.
? ?
Without the written authorization of the test lab., the Test Report may not be copied.
? ?
This test report is only applicable to European Community.
6F, No. 106, Sec. 1, Hsin Tai Wu Rd., Hsi Chih, Taipei Hsien, Taiwan, R.O.C.
SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255
CE TEST REPORT
according to
EN61000-4-11:1994 )
: CRW1232 PRO; CDRW121032A
AOpen Inc.
:
24F,100, Sec. 1, Hsin Tai Wu Rd., Hsichih,
Taipei Hsien, 221, Taiwan, R.O.C.
SPORTON International Inc.
Report No. : C121401
Page Number
: 1 of 62
Issued Date
: Feb. 21, 2001

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CRW1232 PRO and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for AOpen CRW1232 PRO

  • Page 1 ( EN61000-4-2:1995, EN61000-4-3:1996, EN61000-4-4:1995, EN61000-4-5:1995, EN61000-4-6:1996, EN61000-4-8:1993, EN61000-4-11:1994 ) Equipment : CD-RW Model No. : CRW1232 PRO; CDRW121032A AOpen Inc. Applicant 24F,100, Sec. 1, Hsin Tai Wu Rd., Hsichih, Taipei Hsien, 221, Taiwan, R.O.C. The test result refers exclusively to the test presented test model / sample.
  • Page 2: Table Of Contents

    CE TEST REPORT Report No. : C121401 Table of Contents CERTIFICATE OF COMPLIANCE......................4 1. General Description of Equipment under Test ..................5 1.1 Applicant.......................................5 1.2 Manufacturer....................................5 1.3 Basic Description of Equipment under Test...........................5 1.4 Feature of Equipment under Test..............................5 2.
  • Page 3 CE TEST REPORT Report No. : C121401 9.5 Test Points ....................................36 9.6 Photographs of Electrostatic Discharge Immunity Test.......................38 10. Radio Frequency Electromagnetic Field Immunity Test (RS)............39 10.1 Test setup....................................39 10.2 Test Procedure....................................40 10.3 Test Severity Levels..................................40 10.4 Photographs of Radio Frequency Electromagnetic Field Immunity Test..................41 11.
  • Page 4: Certificate Of Compliance

    EN 61000-3-3:1995/A1:1998 and EN 55024:1998 ( EN61000-4-2:1995, EN61000-4-3:1996, EN61000-4-4:1995, EN61000-4-5:1995, EN61000-4-6:1996, EN61000-4-8:1993, EN61000-4-11:1994 ) Equipment : CD-RW Model No. : CRW1232 PRO; CDRW121032A AOpen Inc. Applicant 24F,100, Sec. 1, Hsin Tai Wu Rd., Hsichih, Taipei Hsien, 221, Taiwan, R.O.C. HEREBY...
  • Page 5: General Description Of Equipment Under Test

    Taipei Hsien, 221, Taiwan, R.O.C. 1.2 Manufacturer Same as 1.1. 1.3 Basic Description of Equipment under Test Equipment : CD-RW Model No. : CRW1232 PRO; CDRW121032A Trade Name : AOpen, TDK Power Supply Type : From PC Power Cord : N/A 1.4 Feature of Equipment under Test...
  • Page 6: Test Configuration Of Equipment Under Test

    The SONY Monitor, DELL PS/2 Keyboard, LOGITECH PS/2 Mouse, HP Printer, ACEEX Modem, J-S Earphone and EUT were connected to the AOpen PC for EMI test. c. The HITACHI Monitor, DELL PS/2 Keyboard, PRIMAX PS/2 Mouse, KOKA Headset and EUT were connected to the AOpen PC for EMS test.
  • Page 7 FCC ID : N/A Model No. : H-201 Serial No. : SP00206 Data Cable : Non-Shielded, 1.1m Support Unit 7. -- Personal Computer (AOpen) FCC ID : N/A Model No. : AX33 Power Supply Type : Switching Power Cord : Non-Shielded Serial No.
  • Page 8 FCC ID : N/A Model No. : HD-305 Serial No. : SP0231 Data Cable : Non-Shielded, 1.15m Support Unit 5. -- Personal Computer (AOpen) FCC ID : N/A Model No. : HX45 Power Supply Type : Switching Power Cord : Non-Shielded Serial No.
  • Page 9: Test Software

    CE TEST REPORT Report No. : C121401 3. Test Software < EMI > An executive program, EMITEST.EXE under WIN 98, which generates a complete line of continuously repeating “ H “ pattern was used as the test software. The program was executed as follows : a.
  • Page 10: General Information Of Test

    CE TEST REPORT Report No. : C121401 4. General Information of Test 4.1 Test Facility < EMI > This test was carried out by SPORTON International Inc. Test Site Location No. 3, Lane 238, Kang Lo Street, Nei Hwu District, Taipei 11424, Taiwan, R.O.C.
  • Page 11: Test Of Conducted Powerline

    CE TEST REPORT Report No. : C121401 5. Test of Conducted Powerline Conducted Emissions were measured from 150 kHz to 30 MHz with a bandwidth of 9 kHz on the 230V AC power and return leads of the EUT according to the methods defined in European Standard EN 55022 Clause 9.
  • Page 12: Test Procedures

    CE TEST REPORT Report No. : C121401 5.2 Test Procedures a. The EUT was placed on a desk 0.8 meters height from the metal ground plane and 0.4 meter from the conducting wall of the shielding room and it was kept at least 0.8 meters from any other grounded conducting surface.
  • Page 13: Typical Test Setup Layout Of Conducted Powerline

    CE TEST REPORT Report No. : C121401 5.3 Typical Test Setup Layout of Conducted Powerline 10 cm 80 cm to the ground plane L.I.S.N. L.I.S.N. Page Number : 13 of 62 SPORTON International Inc. TEL : 886-2-2696-2468 Issued Date : Feb. 21, 2001 FAX : 886-2-2696-2255...
  • Page 14: Test Result Of Ac Powerline Conducted Emission

    CE TEST REPORT Report No. : C121401 5.4 Test Result of AC Powerline Conducted Emission 5.4.1 Test mode : READ (COPYTEST)-32X Frequency Range of Test : from 150 kHz to 30 MHz Temperature : 21?C Relative Humidity : 50 % Test Date : Feb.
  • Page 15 CE TEST REPORT Report No. : C121401 5.4.2 Test mode : WRITE (NERO)-12X Frequency Range of Test : from 150 kHz to 30 MHz Temperature : 21?C Relative Humidity : 50 % Test Date : Feb. 15, 2001 The Conducted Emission test was passed at minimum margin LINE 24.768 MHz / 37.30 dBuV. Freq.
  • Page 16: Photographs Of Conducted Powerline Test Configuration

    CE TEST REPORT Report No. : C121401 5.5 Photographs of Conducted Powerline Test Configuration ?? The photographs show the configuration that generates the maximum emission. READ (COPYTEST)-32X FRONT VIEW REAR VIEW Page Number : 16 of 62 SPORTON International Inc. TEL : 886-2-2696-2468 Issued Date : Feb.
  • Page 17 CE TEST REPORT Report No. : C121401 ?? The photographs show the configuration that generates the maximum emission. WRITE (NERO)-12X FRONT VIEW REAR VIEW Page Number : 17 of 62 SPORTON International Inc. TEL : 886-2-2696-2468 Issued Date : Feb. 21, 2001 FAX : 886-2-2696-2255...
  • Page 18: Test Of Radiated Emission

    CE TEST REPORT Report No. : C121401 6. Test of Radiated Emission Radiated emissions from 30 MHz to 1000 MHz were measured with a bandwidth of 120 kHz according to the methods defines in European Standard EN 55022, Clause 10. The EUT was placed on a nonmetallic stand in the open-field site, 0.8 meter above the ground plane, as shown in section 6.3.
  • Page 19: Test Procedures

    CE TEST REPORT Report No. : C121401 6.2 Test Procedures a. The EUT was placed on a rotatable table top 0.8 meter above ground. The EUT was set 10 meters from the interference-receiving antenna which was mounted on the top of a variable height antenna tower.
  • Page 20: Typical Test Setup Layout Of Radiated Emission

    CE TEST REPORT Report No. : C121401 6.3 Typical Test Setup Layout of Radiated Emission Antenna FRP Room Equipment under Test 10 M 0.8 M Ground Plane Receiver TurnTable Page Number : 20 of 62 SPORTON International Inc. TEL : 886-2-2696-2468 Issued Date : Feb.
  • Page 21: Test Result Of Radiated Emission

    CE TEST REPORT Report No. : C121401 6.4 Test Result of Radiated Emission 6.4.1 Test mode : READ (COPYTEST)-32X Frequency Range of Test : from 30 MHz to 1000 MHz Test Distance : 10 M Temperature : 20?C Relative Humidity : 61 % Test Date : Feb.
  • Page 22 CE TEST REPORT Report No. : C121401 6.4.2 Test mode : WRITE (NERO)-12X Frequency Range of Test : from 30 MHz to 1000 MHz Test Distance : 10 M Temperature : 20?C Relative Humidity : 61 % Test Date : Feb. 14, 2001 Emission level (dBuV/m) = 20 log Emission level (uV/m) Corrected Reading : Antenna Factor + Cable Loss + Reading = Emission The Radiated Emission test was passed at minimum margin:...
  • Page 23: Photographs Of Radiated Emission Test Configuration

    CE TEST REPORT Report No. : C121401 6.5 Photographs of Radiated Emission Test Configuration ?? The photographs show the configuration that generates the maximum emission. READ (COPYTEST)-32X FRONT VIEW REAR VIEW Page Number : 23 of 62 SPORTON International Inc. TEL : 886-2-2696-2468 Issued Date : Feb.
  • Page 24 CE TEST REPORT Report No. : C121401 ?? The photographs show the configuration that generates the maximum emission. WRITE (NERO)-12X FRONT VIEW REAR VIEW Page Number : 24 of 62 SPORTON International Inc. TEL : 886-2-2696-2468 Issued Date : Feb. 21, 2001 FAX : 886-2-2696-2255...
  • Page 25: Harmonics Test

    CE TEST REPORT Report No. : C121401 7. Harmonics Test 7.1 Standard Standard : EN 61000-3-2:1995/A12:1996/A13:1997/A1:1998/A2:1998 7.2 Test Procedure The measured values of the harmonics components of the input current, including line current and neutral current, shall be compared with the limits given in Clause 7 of EN 61000-3-2. 7.3 Test Equipment Settings Line Voltage : 230 V Line Frequency : 50 Hz...
  • Page 26: Current Harmonics Test

    CE TEST REPORT Report No. : C121401 7.5 Current Harmonics Test 7.5.1 Test Data Of Current Harmonics PASS FINAL TEST RESULT : Fundamental Current 0.261 A Real Power 61.5 W Power Factor 0.508 Percent in Envelope 100.0 % 20 ℃ Temperature Relative Humidity 49% RH...
  • Page 27 CE TEST REPORT Report No. : C121401 7.5.2 Test Graph Of Harmonics Page Number : 27 of 62 SPORTON International Inc. TEL : 886-2-2696-2468 Issued Date : Feb. 21, 2001 FAX : 886-2-2696-2255...
  • Page 28: Voltage Fluctuations Test

    CE TEST REPORT Report No. : C121401 8. Voltage Fluctuations Test 8.1 Standard Standard : EN 61000-3-3:1995/A1:1998 8.2 Test Procedure The equipment shall be tested under the conditions of Clause 5. The total impedance of the test circuit, excluding the appliance under test, but including the internal impedance of the supply source, shall be equal to the reference impedance.
  • Page 29: Test Result Of Voltage Fluctuation And Flicker Test

    CE TEST REPORT Report No. : C121401 8.5 Test Result Of Voltage Fluctuation And Flicker Test 8.5.1 Test Data Of Voltage Fluctuation And Flicker PASS FINAL TEST RESULT : 20 ℃ Temperature Relative Humidity 49% RH Test Date Feb. 16, 2001 Dc ( % ) Dmax ( % ) Dt ( % )
  • Page 30 CE TEST REPORT Report No. : C121401 8.5.2 Test Graph Of Voltage Fluctuation And Flicker Page Number : 30 of 62 SPORTON International Inc. TEL : 886-2-2696-2468 Issued Date : Feb. 21, 2001 FAX : 886-2-2696-2255...
  • Page 31: Photographs Of Harmonics Test, Voltage Fluctuation And Flicker Test

    CE TEST REPORT Report No. : C121401 8.6 Photographs Of Harmonics Test, Voltage Fluctuation And Flicker Test FRONT VIEW REAR VIEW Page Number : 31 of 62 SPORTON International Inc. TEL : 886-2-2696-2468 Issued Date : Feb. 21, 2001 FAX : 886-2-2696-2255...
  • Page 32: Electrostatic Discharge Immunity Test (Esd)

    CE TEST REPORT Report No. : C121401 9. Electrostatic Discharge Immunity Test (ESD) Pass Performance Criteria Basic Standard EN 61 000-4-2:1995 Generic Standard EN 55024:1998 Level 3 for air discharge, 2 for contact discharge ?2 / ?4 / ?8 KV for air discharge, Tested voltage ?2 / ?4 KV for contact discharge 16 ?C...
  • Page 33: Test Setup For Tests Performed In Laboratory

    CE TEST REPORT Report No. : C121401 9.2 Test Setup for Tests Performed in Laboratory A ground reference plane was provided on the floor of the test site. It was a metallic sheet (copper or aluminum) of 0.25 mm, minimum thickness; other metallic may be used but they shall have at least 0.65 mm thickness.
  • Page 34: Esd Test Procedure

    CE TEST REPORT Report No. : C121401 9.3 ESD Test Procedure a. In the case of air discharge testing the climatic conditions shall be within the following ranges: - ambient temperature: 15℃ to 35℃; - relative humidity : 30% to 60%; - atmospheric pressure : 68 KPa (680 mbar) to 106 KPa (1060 mbar).
  • Page 35: Test Severity Levels

    CE TEST REPORT Report No. : C121401 9.4 Test Severity Levels 9.4.1 Contact Discharge Level Test Voltage (KV) of Contact discharge Specified Remark : “X” is an open level. 9.4.2 Air Discharge Level Test Voltage (KV) of Air Discharge Specified Remark : “X”...
  • Page 36: Test Points

    CE TEST REPORT Report No. : C121401 9.5 Test Points 9.5.1 Test Result of Air Discharge Test Point Voltage Tested No. Observation Result ?2 / ?4 / ?8 KV Case BY 10 NORMAL PASS ?2 / ?4 / ?8 KV Earphone jack BY 10 NORMAL...
  • Page 37 CE TEST REPORT Report No. : C121401 9.5.2 Test Result of Contact Discharge Polarity Voltage Tested No. Observation Result ?2 / ?4 KV Horizontal(At Front) BY 25 NORMAL PASS ?2 / ?4 KV Horizontal (At Left) BY 25 NORMAL PASS ?2 / ?4 KV Horizontal (At Right) BY 25...
  • Page 38: Photographs Of Electrostatic Discharge Immunity Test

    CE TEST REPORT Report No. : C121401 9.6 Photographs of Electrostatic Discharge Immunity Test FRONT VIEW REAR VIEW Page Number : 38 of 62 SPORTON International Inc. TEL : 886-2-2696-2468 Issued Date : Feb. 21, 2001 FAX : 886-2-2696-2255...
  • Page 39: Radio Frequency Electromagnetic Field Immunity Test (Rs)

    CE TEST REPORT Report No. : C121401 10. Radio Frequency Electromagnetic Field Immunity Test (RS) Pass Performance Criteria Basic Standard EN 61 000-4-3:1996 Generic Standard EN 55024:1998 Level Frequency Range 80-1000 MHz Field Strength 3 V/m (Modulated 80% AM) 21 ?C Temperature Relative Humidity 53 %...
  • Page 40: Test Procedure

    CE TEST REPORT Report No. : C121401 10.2 Test Procedure a. The equipment to be tested is placed in the center of the enclosure on a wooden table. The equipment is then connected to power and signal leads according to pertinent installation instructions. b.
  • Page 41: Photographs Of Radio Frequency Electromagnetic Field Immunity Test

    CE TEST REPORT Report No. : C121401 10.4 Photographs of Radio Frequency Electromagnetic Field Immunity Test FRONT VIEW REAR VIEW Page Number : 41 of 62 SPORTON International Inc. TEL : 886-2-2696-2468 Issued Date : Feb. 21, 2001 FAX : 886-2-2696-2255...
  • Page 42: Electrical Fast Transient/Burst Immunity Test (Eft/Burst)

    CE TEST REPORT Report No. : C121401 11. Electrical Fast Transient/Burst Immunity Test (EFT/BURST) Pass Performance Criteria Basic Standard EN 61 000-4-4:1995 Generic Standard EN 55024:1998 Level on Power Supply -- 2 Tested voltage on Power Supply -- 0.5/1.0 KV Temperature 20?C Relative Humidity...
  • Page 43: Test On Power Line

    CE TEST REPORT Report No. : C121401 The EUT was placed on a ground reference plane and was insulated from it by an insulating support about 0.1m thick. If the EUT is table-top equipment, it was located approximately 0.8m above the GRP.. The GRP. was a metallic sheet (copper or aluminum) of 0.25 mm ,minimum thickness;...
  • Page 44: Test Procedure

    CE TEST REPORT Report No. : C121401 11.4 Test Procedure a. In order to minimize the effect of environmental parameters on test results, the climatic conditions when test is carrying out shall comply with the following requirements: - ambient temperature: 15℃ to 35℃; - relative humidity : 45%...
  • Page 45: Test Severity Levels

    CE TEST REPORT Report No. : C121401 11.5 Test Severity Levels The following test severity levels are recommended for the fast transient/burst test : Open circuit output test voltage ± 10% Level On Power Supply On I/O signal, data and control line 0.5 KV 0.25 KV 1.0 KV...
  • Page 46: Photographs Of Electrical Fast Transient/Burst Immunity Test

    CE TEST REPORT Report No. : C121401 11.6 Photographs of Electrical Fast Transient/BURST Immunity Test FRONT VIEW REAR VIEW Page Number : 46 of 62 SPORTON International Inc. TEL : 886-2-2696-2468 Issued Date : Feb. 21, 2001 FAX : 886-2-2696-2255...
  • Page 47: Surge Immunity Test

    CE TEST REPORT Report No. : C121401 12. SURGE IMMUNITY TEST Pass performance Criteria : Basic Standard EN 61 000-4-5 (1995) Generic Standard EN 55 024:1998 Input Voltage, Frequency 230Vac, 50Hz Level ?1.0 / ? 2.0 KV Test Voltage Temperature 19 °...
  • Page 48: Test Level

    CE TEST REPORT Report No. : C121401 12.2 TEST LEVEL Level Open-circuit test voltage, ± 10%, KV Specified NOTE - x is an open class. This level can be specified in the product specification. 12.3 TEST PROCEDURE Climatic conditions The climatic conditions shall comply with the following requirements : ambient temperature : 15 ℃...
  • Page 49: Operating Condition

    CE TEST REPORT Report No. : C121401 phase angle in the case of a.c. power supply; actual installation conditions, for example : AC : neutral earthed, DC : ( + ) or ( - ) earthed to simulated the actual earthing conditions. If not otherwise specified the surges have to be applied synchronized to the voltage phase at the zero-crossing and the peak value of the a.c.
  • Page 50: Photographs Of Surge Immunity Test

    CE TEST REPORT Report No. : C121401 12.5 Photographs of SURGE IMMUNITY TEST FRONT VIEW REAR VIEW Page Number : 50 of 62 SPORTON International Inc. TEL : 886-2-2696-2468 Issued Date : Feb. 21, 2001 FAX : 886-2-2696-2255...
  • Page 51: Conducted Disturbances Induced By Radio-Frequency Field Immunity Test ( Cs )

    CE TEST REPORT Report No. : C121401 13. CONDUCTED DISTURBANCES INDUCED BY RADIO-FREQUENCY FIELD IMMUNITY TEST ( CS ) Pass performance Criteria : Basic Standard EN 61 000-4-6 (1996) Generic Standard EN 55 024 :1998 Input Voltage, Frequency AC 230V, 50Hz Level Test Voltage 3 V/rms ( Modulated, 1KHz, 80%, AM )
  • Page 52: Test Procedure

    CE TEST REPORT Report No. : C121401 13.3 TEST PROCEDURE The EUT shall be operated within its intended climatic conditions. The temperature and relative humidity should be recorded. This test method test can be performed without using a sell shielded enclosure. This is because the disturbance levels applied and the geometry of the setups are not likely to radiated a high amount of energy, especially at the lower frequencies.
  • Page 53: Power Frequency Magnetic Field Immunity Tests

    CE TEST REPORT Report No. : C121401 14. Power Frequency Magnetic Field immunity tests Pass performance Criteria : Basic Standard EN 61000-4-8 ( 1993 ) Generic Standard EN 55 024 :1998 Input Voltage, Frequency AC 230V, 50Hz Temperature 19 ° C Relative Humidity 51 % Test Date...
  • Page 54: Photographs Of Power Frequency Magnetic Field Immunity Tests

    CE TEST REPORT Report No. : C121401 14.4 Photographs of Power Frequency Magnetic Field immunity tests FRONT VIEW REAR VIEW Page Number : 54 of 62 SPORTON International Inc. TEL : 886-2-2696-2468 Issued Date : Feb. 21, 2001 FAX : 886-2-2696-2255...
  • Page 55: Voltage Dips And Voltage Interruptions Immunity Tests

    CE TEST REPORT Report No. : C121401 15. VOLTAGE DIPS AND VOLTAGE INTERRUPTIONS IMMUNITY TESTS Pass performance Criteria : C for voltage interruption, B for voltage dips Basic Standard EN 61 000-4-11 ( 1994 ) Generic Standard EN 55 024:1998 Input Voltage, Frequency AC 230V, 50Hz Temperature...
  • Page 56: Testing Requirement And Procedure

    CE TEST REPORT Report No. : C121401 15.3 TESTING REQUIREMENT AND PROCEDURE The test was based on EN 61 000-4-11 (1994) 15.4 TEST CONDITIONS 1. Source voltage and frequency : 230V / 50Hz, Single phase. 2. Test of interval : 10 sec. 3.
  • Page 57: Photographs Of Voltage Dips And Voltage Interruptions Immunity Tests

    CE TEST REPORT Report No. : C121401 15.6 Photographs of VOLTAGE DIPS AND VOLTAGE INTERRUPTIONS IMMUNITY TESTS FRONT VIEW REAR VIEW Page Number : 57 of 62 SPORTON International Inc. TEL : 886-2-2696-2468 Issued Date : Feb. 21, 2001 FAX : 886-2-2696-2255...
  • Page 58: Antenna Factor & Cable Loss

    CE TEST REPORT Report No. : C121401 16. Antenna Factor & Cable Loss Frequency (MHz) Antenna Factor (dB) Cable Loss (dB) 20.1 20.9 18.7 15.0 11.8 11.6 13.3 13.8 13.6 12.1 10.1 11.2 12.4 13.1 13.3 13.4 14.0 14.5 15.0 15.3 15.6 16.8...
  • Page 59: List Of Measuring Equipment Used

    CE TEST REPORT Report No. : C121401 17. List of Measuring Equipment Used <EMI> Instrument Manufacturer Model No. Serial No. Characteristics Calibration Date Remark Test Receiver R&S ESH3 893495/013 9KHz – 30MHz Jun. 19, 2000 Conduction Spectrum Monitor R&S 894987/011 Jun.
  • Page 60 CE TEST REPORT Report No. : C121401 <EMS> Instrument Manufacturer Model No. Characteristics Calibration Date Remark ESD Simulator KEYTEK MZ-15/EC 0 KV - 15 KV Apr. 14, 2000 OMNI-Tip KEYTEK TPC-2 0 KV - 15 KV Jul. 23, 2000 Amplifier 100W 1000M3 80 MHz - 1 GHz Isotropic Field Probe...
  • Page 61: Notice For Class A Product

    CE TEST REPORT Report No. : C121401 18. Notice for Class A Product This Notice is for class A product only. If the Equipment under Test is a class B product, this notice should be disregarded. Class A ITE is a category of all other ITE which satisfies the class A ITE limits but not the class B ITE limits. Such equipment should not be restricted in its sale but the following warning shall be included in the instructions for use: Warning...
  • Page 62: Declaration Of Conformity And The Ce Mark

    CE TEST REPORT Report No. : C121401 19. Declaration of Conformity and the CE Mark There are three possible procedures pertaining to the declaration of conformity : 19.1 Conformity Testing and Declaration of Conformity by the Manufacturer or His Authorized Representative Established within the Community or by an Importer. - Article 10 (1) of the EMC Directive, - §...