CE TEST REPORT

7. Harmonics Test

7.1 Standard

Standard
??

7.2 Test Procedure

The measured values of the harmonics components of the input current, including line current and neutral
current, shall be compared with the limits given in Clause 7 of EN 61000-3-2.

7.3 Test Equipment Settings

Line Voltage : 230 V
??
Line Frequency : 50 Hz
??
Device Class : D
??
Current Measurement Range : High
??
Measurement Delay : 10.0 seconds
??
Test Duration : 2.00 minutes
??
Class determination Pre-test Duration : 10.00 seconds
??

7.4 Test Setup

SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255
: EN 61000-3-2:1995/A12:1996/A13:1997/A1:1998/A2:1998
Report No. : C121401
Page Number
: 25 of 62
Issued Date
: Feb. 21, 2001