CE TEST REPORT

12.2 TEST LEVEL

Level
1
2
3
4
x
NOTE - x is an open class.
This level can be specified in the product specification.

12.3 TEST PROCEDURE

a.
Climatic conditions
The climatic conditions shall comply with the following requirements :
ambient temperature : 15 ℃ to 35 ℃
--
--
relative humidity : 10 % to 75 %
--
atmospheric pressure : 86 kPa to 106 kPa ( 860 mbar to 1060 mbar )
b.
Electromagnetic conditions
The electromagnetic environment of the laboratory shall not influence the test results.
c.
The test shall be performed according the test plan that shall specify the test set-up with
--
generator and other equipment utilized;
--
test level ( voltage/current );
--
generator source impedance;
--
internal or external generator trigger;
--
number of tests : at least five positive and five negative at the selected points;
--
repetition rate : maximum 1/min.
--
inputs and outputs to be tested;
--
representative operating conditions of the EUT;
--
sequence of application of the surge to the circuit;
SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255
Open-circuit test voltage, ± 10%, KV
0.5
1.0
2.0
4.0
Specified
Report No. : C121401
Page Number
: 48 of 62
Issued Date
: Feb. 21, 2001