CE TEST REPORT

10.2 Test Procedure

a. The equipment to be tested is placed in the center of the enclosure on a wooden table. The equipment
is then connected to power and signal leads according to pertinent installation instructions.
b. The bilog antenna which is enabling the complete frequency range of 80-1000 MHz is placed 3m away
from the equipment. The required field strength is determined by placing the field strength meter(s) on
top of or directly alongside the equipment under test and monitoring the field strength meter via a remote
field strength indicator outside the enclosure while adjusting the continuous-wave to the applicable
antennae.
c. The test is normally performed with the antenna facing the most sensitive side of the EUT. The
polarization of the field generated by the biconical antenna necessitates testing each position twice,
once with the antenna positioned vertically and again with the antenna positioned horizontally. The
circular polarization of the field from the log-spiral antenna makes a change of position of the antenna
unnecessary.
d. At each of the above conditions, the frequency range is swept 80-1000 MHz, pausing to adjust the R.F.
signal level or to switch oscillators and antenna. The rate of sweep is in the order of 1.5*10-3 decades/s.
The sensitive frequencies or frequencies of dominant interest may be discretely analyzed.

10.3 Test Severity Levels

Frequency Band : 80-1000 MHz
Remark : "X" is an open class.
Test Engineer :
SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255
Level
1
2
3
X
ROXY CHOU
Test field strength (V/m)
1
3
10
Specified
Report No. : C121401
Page Number
: 40 of 62
Issued Date
: Feb. 21, 2001