CE TEST REPORT
5.4.2 Test mode : WRITE (NERO)-12X
? ?
Frequency Range of Test : from 150 kHz to 30 MHz
? ?
Temperature : 21?C
? ?
Relative Humidity : 50 %
? ?
Test Date : Feb. 15, 2001
The Conducted Emission test was passed at minimum margin LINE 24.768 MHz / 37.30 dBuV.
Freq.
Line
or
(MHz) Neutral
0.156
L
1.023
L
24.768 L
0.157 N
1.024 N
24.767 N
Test Engineer :
SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255
Meter Reading
Q.P.
A.V.
Q.P.
(dBuV) (dBuV)
(uV)
50.10
19.50 319.89
32.80
28.80
43.65
40.30
37.30 103.51
50.50
20.20 334.97
33.10
28.90
45.19
39.90
37.10
98.86
LOUIS LIN
A.V.
Q.P.
A.V.
(uV)
(dBuV)
(dBuV)
9.44
65.67
55.67 1921.82 607.73
27.54
56.00
46.00
73.28
60.00
50.00 1000.00 316.23
10.23
65.62
55.62
27.86
56.00
46.00
71.61
60.00
50.00 1000.00 316.23
Report No. : C121401
Limits
Q.P.
A.V.
(uV)
(uV)
630.96 199.53
1910.11
604.03
630.96 199.53
Page Number
Issued Date
Margin
Q.P.
A.V.
(dB)
(dB)
-15.6 -36.2
-23.2 -17.2
-19.7 -12.7
-15.1 -35.4
-22.9 -17.1
-20.1 -12.9
: 15 of 62
: Feb. 21, 2001