CE TEST REPORT
8. Voltage Fluctuations Test
8.1 Standard
Standard
??
8.2 Test Procedure
The equipment shall be tested under the conditions of Clause 5.
The total impedance of the test circuit, excluding the appliance under test, but including the internal
impedance of the supply source, shall be equal to the reference impedance. The stability and tolerance of
the reference impedance shall be adequate to ensure that the overall accuracy of ? 8% is achieved during the
whole assessment procedure.
8.3 Test Equipment Settings
Line Voltage : 230 V
??
Line Frequency : 50 Hz
??
Measurement Delay : 10.0 seconds
??
Pst Integration Time : 10 minutes
??
Pst Integration Periods : 1
??
Test Duration : 00:10:00 minutes
??
8.4 Test Setup
SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255
: EN 61000-3-3:1995/A1:1998
Report No. : C121401
Page Number
: 28 of 62
Issued Date
: Feb. 21, 2001