CE TEST REPORT

5.2 Test Procedures

a. The EUT was placed on a desk 0.8 meters height from the metal ground plane and 0.4 meter from the
conducting wall of the shielding room and it was kept at least 0.8 meters from any other grounded
conducting surface.
b. Connect EUT to the power mains through a line impedance stabilization network (LISN).
c. All the support units are connect to the other LISN.
d. The LISN provides 50 ohm coupling impedance for the measuring instrument.
e. The CISPR states that a 50 ohm , 50 microhenry LISN should be used.
f. Both sides of AC line were checked for maximum conducted interference.
g. The frequency range from 150 kHz to 30 MHz was searched.
h. Set the test-receiver system to Peak Detect Function and Specified Bandwidth with Maximum Hold
Mode.
i. If the emission level of the EUT in peak mode was 6 dB lower than the limit specified, then testing will
be stopped and peak values of EUT will be reported, otherwise, the emissions which do not have 6 dB
margin will be retested one by one using the quasi-peak method and/or average methods and
reported.
SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255
Report No. : C121401
Page Number
: 12 of 62
Issued Date
: Feb. 21, 2001