CE TEST REPORT

5. Test of Conducted Powerline

Conducted Emissions were measured from 150 kHz to 30 MHz with a bandwidth of 9 kHz on the 230V AC
power and return leads of the EUT according to the methods defined in European Standard EN 55022 Clause
9. The EUT was placed on a nonmetallic stand in a shielded room 0.8 meters above the ground plane as
shown in section 5.3. The interface cables and equipment positioning were varied within limits of reasonable
applications to determine the position producing maximum conducted emissions.

5.1 Description of Major Test Instruments

?? Test Receiver
Attenuation
Start Frequency
Stop Frequency
Step MHz
IF Bandwidth
SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255
( R&S ESH3 )
0 dB
0.15 MHz
30 MHz
0.007 MHz
9 KHz
Report No. : C121401
Page Number
: 11 of 62
Issued Date
: Feb. 21, 2001