9.2 - POSITIONING
During installation, carry out a good levelling
of the machine in order to let it work properly
(doors, basket forward feeding).
In order to do so use the adjustable feet.
After removing front panels, position the
machine over the connections. Assemble the
inlet and outlet shelves for basket loading and
unloading. The limit switch FC1 is located on
the outlet shelf or on the machine delivery if
the shelf is not provided for. The limit switch
shall be connected to the outlet shelf.
The machine shall also be equipped with
detergent and brightener dispenser, which
shall be supplied by the manufacturer of these
products.
To connect the dispensers there are four light
blue terminals, marked with apposite labels,
which are energized when the pump is
working. To avoid damages to the electrical
components it is compulsory to use these
terminals and avoid movable connections in
other points of the plant.
Terminal voltage corresponds to line voltage.

ELECTRICAL CONNECTION

Before connecting the machine, check to
make sure the voltage outlet of the mains
is the same as the voltage specified on the
data plate of the machine.
WARNING: Danger to life due to live components!
During all electrical operations, disconnect the machine
from the network and verify the absence of
power.
The machine and its accessories must be connected in
accordance with local regulation, by a company
that is specialized in electrical installation
authorized by the competent authorities.
It is also necessary to check that the counter,
the mains and the intake are adequately
dimensioned
to
withstand
maximum load.
the
required
57
A main switch must be installed between the
mains and the machine. This safety measure
also requires that the minimum distance
between the switch contacts is at least 3 mm
and the disconnection on all poles according
to EN 60204 (VDE 113).
The mains must be wired to be able to handle
the current drawn by the machine. The
system must also be provided with a proper
ground lead in accordance with the existing
norms. The electric cable must be of the
following type H07RN-F.
For a correct selection of the cable rated
cross-section refer to the data reported on the
product data plate.
The cable cross-section shall not be inferior
to the one indicated in the "Technical data
and description" reported in the first page of
the present manual.
The cable shall be connected to the isolator
IA1
and
to
the
terminal, it shall be made passed and
stopped by means of the apposite cable grip.
adjacent
yellow-green