Technical specifications
Type
Temperature range
Operation
Storage
Relative humidity
Protection class as per EN 60529 plug
connector inserted or provided with
protective cap
Protection against electric shock
(protection against direct and indirect
contact as per IEC/DIN EN 60204−1)
Protection against explosion
(as per EU guideline 94/9/
EG, EN 50021 and EN 50281−1−1)
Do not disconnect electrical connec
tions which are under tension.
Elektromagnetic compatibility
Interference emitted
Immunity against interference
1)
The component is intended for industrial use.
Festo CPV..GE−DI01−8 0503b English
CPV..−DI01
− 5 °C ... + 50 °C
− 20 °C ... + 70 °C
95 %, non−condensing
IP65
by means of PELV circuits
(Protective Extra−Low
Voltage)
II 3 G/D EEx nA II T5 X
− 5 °C Ta + 50 °C
T 80 °C IP65 (Year of manu
facture see Ex−identification
on the product)
Tested as per DIN EN
61000−6−4 (industry)
Tested as per DIN EN
61000−6−2 (industry)