7 Activating the «<Remote control»> key
Tab. 2
Precondition
10
7
Activating the «<Remote control»> key
Further settings have to be made to allow the machine to be remotely controlled.
➤ Refer to the section "Additional information" in this chapter.

Activating/deactivating the check box

Check box
Check box status
The following menus are used to activate the «Remote control» key:
<Compressor ON>
Menu
<Load control>
Menu
The function will be available as soon as the «Remote control» key in one of the menus has been
activated.
Password level 2 is activated.
The display shows the operating mode.
Activating the «Remote control» key in the Compressor ON menu
1. Press «Enter».
The main menu is displayed.
2. Select
< Configuration ➙ Compressor start ➙ Compressor on > .
3. Press «DOWN» repeatedly until
4. Press «Enter» to switch into setting mode.
check box for «Remote control» key will flash.
The
8 9 p s i
0 8 : 1 5
5.4.1 Compressor on
Local mode: Key
Remote mode: Key
------------------------------
RC DI 1.12 ☐
Key remote: ☐
Key clock: ☐
5. Press the «UP» key.
The activated check box is displayed.
Quick user guide
Controller
SIGMA CONTROL 2 SCREW FLUID 1.1.3
Status
activated
deactivated
Key remote is displayed as active line.
1 7 6 ° F
Menu
Active line with check box
9_9450 03 USE