OPERATION

AC OPERATION

If an appliance begins to operate abnormally, becomes sluggish, or stops
suddenly, turn it off immediately. Disconnect the appliance, and determine
whether the problem is in the appliance or the rated load capacity of the
generator has been exceeded.
Substantial overloading that continuously lights the red OVERLOAD ALARM
indicator may damage the generator. Marginal overloading that temporarily lights
the red OVERLOAD ALARM indicator may shorten the service life of the generator.
1. Turn the voltage selector switch to either position.
With the voltage selector switch in the "120 V/240 V" position, you can use
the 120 V and 120 V/240 V receptacles simultaneously. If you are NOT using
the 120 V/240 V receptacle, then select the "120 V ONLY" position.
2. Start the engine and make sure
the green OUTPUT indicator
comes on.
60
VOLTAGE SELECTOR SWITCH
OUTPUT INDICATOR (GREEN)
120 V/240 V
120 V ONLY