7.3 Engine
Type:
Performance:
Speed:
Weight:
Diameter of exhaust gas pipe:
Discharge heat exchanger:
Amount of oil:
Type of oil:
Warning
During the initial running time, use "John Deere
Break-in" oil (TY22041) for refilling.
Oil pressure:
Amount of cooling liquid:
Cooling liquid:
Coolant:
Warning
Never use conventional engine vehicle coolants.
They can damage the engine due to their high
silicate content!
Cooling water temperature:
Fuel filling quantity:
Fuel type:
Permissible counter-pressure
exhaust gas:

7.4 Battery

2 x CLT120-12 with 12 V - 120 Ah.
Battery dimensions L x W x H:
Weight
The battery is maintenance-free.

7.5 Controller

Type:
Control cabinet:
Enclosure class:
Dimensions W x H x D:
Weight:
Supply voltage:
Voltage tolerance:
Maximum current consumption
(incl. cooling water heater):
EMC-noise emission:
EMC-noise immunity:
Degree of contamination:
Control voltage:
Battery charger power supply:
Battery voltage:
Maximum battery capacity:
Battery type:
Fuse battery charger:
The standard alarm relays are located on the main I/O board.
Additionally, 19 alarm relays can be ordered for connecting
remote indicators. All relays have DPDT contacts rated for 8 A,
240 VAC.
28
4-stroke diesel engine.
See section 19.2.
See section 19.2.
See section 19.2.
See section 19.2.
3/8".
See section 19.2.
API-classification CF4.
Viscosity 15W-40.
See section 19.2.
See section 19.2.
Mixture of 50 % coolant and
50 % water.
Ethylene/glycol-coolant
according to ASTM D 4985.
71 to 93 °C.
See section 19.2.
Diesel.
0.075 bar.
410 x 177 x 225 mm.
38 kg.
Tornatech GPD.
Sheet steel, red.
IP24.
24" x 36" x 8".
Appr. 68 kg.
1 x 220 V, 50/60 Hz.
± 10 %.
30 A.
According to EN 61000-6-3.
According to EN 61000-6-2.
2.
230 V/12 V.
12 V.
12 V.
120 Ah.
CLT (Pb).
SLO-BLO 3AG-32VDC 20A.

8. Operating conditions

Warning
Do not operate the pump at any pressure, flow
rate or liquid temperature other than those for
which the pump was originally purchased. Do not
pump any other liquid than the one for which the
pump was originally purchased without the
consent of Grundfos or its authorised
representatives. Disregard of this warning can
result in pump failure and serious personal injury
or death.

8.1 Minimum inlet pressure

At any time, there must be a positive inlet pressure. A minimum
inlet pressure of 5 psi is recommended.
Inadequate inlet pressure will result in cavitation
Caution
damage to the impeller and casing.

8.2 Maximum inlet pressure

The sum of actual inlet pressure plus pump pressure against a
closed valve must always be lower than the maximum
permissible operating pressure. See section 8.7 Maximum
operating pressure. The maximum inlet pressure is 100 psi
(approx. 7 bar).

8.3 Minimum flow rate

Generally, the pump is not allowed to run against
a closed valve, as this may cause an increase in
Caution
temperature or formation of steam in the pump.
This may cause damage to the pump.
Only brief periods of operation during start and stop are
permissible with a closed discharge valve. Prolonged operation at
less than 15 to 20 % of the pump's rated capacity will cause
heating of the pumped liquid, impeller erosion, short life of
bearings and packing due to stress or vibration. Some pumps
may incur shaft damage and wear on stationary parts.
It is therefore advisable to install a bypass pipe to ensure a
minimum flow rate of at least 2 % at maximum efficiency. The
minimum flow rate helps to dissipate any excessive heat and thus
protect the pump against overheating.
Operation of the pump with flow only through the
Caution
bypass is not allowed.
How to install a bypass is shown in section 9.6 Bypass.

8.4 Pumped liquids

The pumps are suitable for clean and non-aggressive water, not
containing solid particles or fibres.

8.5 Liquid temperature

Maximum permissible liquid temperature is 40 °C. The pumps
can handle temperatures from 0 °C to +120 °C.

8.6 Pump speed

The maximum pump speed is stated on the test report and shown
on the nameplate for the fire pump set. See fig. 15, pos. 11.

8.7 Maximum operating pressure

10, 16 or 25 bar.
The maximum operating pressure is stated on the pump
nameplate.