GILES FSH-2 Operation & Service Manual page 56

Hide thumbs Also See for FSH-2:
Table of Contents

Advertisement

Model: FSH-2, FSH-2A-99
6-01.
Troubleshooting Procedures - continued
Problem
Fryer will not power-up:
light ON
[HOOD POWER]
• [
light ON
FILTER MISSING]
• [FRYER POWER] light OFF
Fryer will not power-up:
light ON
[HOOD POWER]
• [
light OFFN
FILTER MISSING]
light OFF
[FRYER POWER]
• No alarm sounding
Fryer will not power-up:
light ON
[HOOD POWER]
• Continuous (steady) tone alarm
sounding.
light OFF
[FRYER POWER]
Fryer will not power-up:
light ON
[HOOD POWERED]
light ON
[WASH]
• Intermittent (beeping) tone alarm
sounding.
• [FRYER POWER] light OFF
Fryer is ON:
light ON
[HOOD POWER]
light ON
[CHECK]
• No alarm sounding, but cell is NOT
cleaning air.
46
Probable Cause
a. Baffle filter is missing or not
properly installed
b. Charcoal filter is missing or not
properly installed
c. Faulty filter switches.
a. Fire Suppression system is not
armed.
b. Ansul switch is faulty
a. Baffle or charcoal filter clogged
b. Hood exhaust outlet excessively
block
c. Vacuum switch is out of
adjustment
d. Kinked or blocked vacuum line
e. Fan running slow or blades are
loaded with grease build-up.
a. Excessive grease film built up on
collector fins; too dirty
b. EAC cell is not installed
c. EAC driver board is faulty
d. Poor connection at contact
plate; dirty contacts, mis-
alignment, faulty contacts.
e. Ionizer wire(s) missing
a. Ionizer wire broken & touching
chassis.
b. Collector fins shorted to ground
by moisture.
Troubleshooting
Corrective Action
Install filter / check positioning.
Install filter / check positioning.
Test & replace as needed.
Contact Ansul service company.
Contact Ansul service company.
Replace charcoal filter with new •
Clean baffle filter.
Clear of any obstructions.
Test & adjust vacuum switch.
Remove vacuum line kinks or
blockage.
Check voltage and inspect blower;
clean if needed
Clean the EAC cell,
Section 4.04.2
Install clean EAC cell.
Test & replace EAC power supply if
needed.
Check cell position, clean contacts,
inspect contact plate & replace if
needed.
Replace missing wire(s)
Replace ionizer wire.
Dry cell, determine cause of
moisture, cool air being drawn into
hood creating condensation.
.