[Source:]List:slew - ITech IT8700 Series Programming Manual

Dc programmable electronic loads
Hide thumbs Also See for IT8700 Series:
Table of Contents

Advertisement

Command Syntax
[SOURce:]LIST:LEVel <NR1>, <NRf>
Parameters
1 to steps, MIN to MAX
Unit
NONE, NONE
Examples
LIST:LEV 1, 10 LIST:LEV 2, 15.2
Query Syntax
[SOURce:]LIST:LEVel? <NR1>
Returned Parameters
<NR3>
Related Commands
LIST:RANG

[SOURce:]LIST:SLEW

This command sets the slew rate for each step. This command programs both
positive and negative going slew rates. MAXimum sets the slew to its fastest
possible rate. MINimum sets the slew to its slowest rate. LIST:SLEW? returns
the number of points programmed.
Command Syntax
[SOURce:]LIST:SLEW[:BOTH] <NR1> ,<NRf>
Parameters
1 to steps, MIN to MAX
Unit
NONE, NONE
Examples
LIST:SLEW 1, 1.5
LIST:SLEW 2, MAX
Copyright © Itech Electronic Co., Ltd.