7 Error Handling
3060 ErrAmplifier
Cause:
Overload, overtemperature at amplifier .
Response:
- Error message.
Actions:
- Restart governor by reset.
- Notify HEINZMANN.
Note:
These parameters are implemented only in the HELENOS series.
3060 ErrFeedbackAdjust2
Cause:
Automatic calibration of the actuator 2 could not be performed, wrong input
of reference values for actuator.
Response:
- Governor cannot be put into operation.
Actions:
- Check voltage supply and supply lines to actuator 2.
- Check feedback cable to actuator 2.
- Check actuator 2, replace actuator 2 if necessary.
- Engine stop switch must be opened (indication parameter 2810 Switch-
EngineStop = 0) to perform automatic calibration of actuator 2 with 2-
quadrant-operation.
- Check reference values and error limits for feeedback
- Programme feedback error limits
1962 FeedbackErrorLow = 0
1963 FeedbackErrorHigh = 65535
store values (
automatic calibration.
- Set error limits again.
Note:
These parameters are implemented only in the PRIAMOS III series.
3061 ErrFeedbackAdjust3
Cause:
Automatic calibration of the actuator 3 could not be performed, wrong input
of reference values for actuator.
Response:
- Governor cannot be put into operation.
Actions:
- Check voltage supply and supply lines to actuator 3.
- Check feedback cable to actuator 3.
- Check actuator 3, replace actuator 3 if necessary.
- Engine stop switch must be opened (indication parameter 2810 Switch-
EngineStop = 0) to perform automatic calibration of actuator 3 with 2-
44
3160 SErrAmplifier
3160 SerrFeedbackAdjust2
↑
, restart governor by reset and repeat
)
3.2 Saving Data
3161 SerrFeedbackAdjust3
Programmer PG 02
Need help?
Do you have a question about the Programmer 2 and is the answer not in the manual?
Questions and answers