Operating and installation instructions REMKO series KWT Monobloc air conditioners Wall-mounted units for cooling and heating KWT 240 DC 0212-2019-10 Edition 3, en_GB Read the instructions prior to performing any task!
Page 2
Read these operating instructions carefully before commis- sioning / using this device! These instructions are an integral part of the system and must R410A always be kept near or on the device. Subject to modifications; No liability accepted for errors or mis- Refrigerant prints! Translation of the original...
Table of contents Safety and usage instructions......................4 1.1 General safety notes........................4 1.2 Identification of notes........................4 1.3 Personnel qualifications........................4 1.4 Dangers of failure to observe the safety notes................4 1.5 Safety-conscious working....................... 4 1.6 Safety notes for the operator......................5 1.7 Safety notes for installation, maintenance and inspection..............
REMKO series KWT Safety and usage instructions CAUTION! This combination of symbol and signal word 1.1 General safety notes warns of a potentially hazardous situation, which if not avoided may cause injury or mate- Carefully read the operating manual before com- rial and environmental damage.
"certificate of warranty" to conditions stipulated in this manual and comply REMKO GmbH & Co. KG at the time when the with all applicable regional regulations. units are purchased and commissioned.
REMKO series KWT 1.11 Transport and packaging The devices are supplied in a sturdy shipping con- tainer. Please check the equipment immediately upon delivery and note any damage or missing parts on the delivery and inform the shipper and your contractual partner. For later complaints can not be guaranteed.
Technical data 2.1 Unit data Series KWT 240 DC Local, two-hose air conditioner with Operating mode inverter technology for cooling and heating 2.35 (0.92-3.10) Nominal cooling output Energy efficiency ratio - cooling 3.22 Energy efficiency rating EER kWh/60 Energy consumption, hourly 0.73 2.36 (1.10-2.67) Nominal heating...
REMKO series KWT Series KWT 240 DC Dimensions - height Dimensions - width 1030 Dimensions - depth Weight EDP no. 1609240 Per EN 14511 Per EN 12102 Contains greenhouse gas per Kyoto protocol (GWP 2088) 2.2 Unit dimensions 1030 1030 Fig.
Design and function the setpoint temperature with minimal temperature fluctuations. Thanks to this inverter technology 3.1 Unit description energy is saved compared to conventional room air conditioners and the noise emissions are The local room air conditioner consists of a com- reduced to a particularly low level.
REMKO series KWT Operation The infrared remote control is operated via a button battery of type CR2430. Replacement is The system can be operated by means of the carried out at the rear of the remote control. Turn touch panel on the unit or via the infrared remote the cover counter-clockwise with a flat object (e.g.
Page 11
Keys and displays of the operating unit and their functions The system can be operated by means of the touch panel on the unit or via the standard infrared remote controller. The functional operation of the keys are identical. Fig. 5: Keys on the remote control The boost function provides a 30 minute perform- "...
Page 12
REMKO series KWT " " key - "Recirculation" mode " " key - Hotel mode Recirculation mode is activated by holding down Hotel mode limits the adjustment range in cooling this key. mode from 22 °C to 28 °C and in heating mode from 16 °C to 24 °C.
Assembly and KWT 240 DC (all measurements in mm) installation 5.1 Important notes prior to installation When installing the unit, observe the following points: The installation must be carried out on a flat Observe minimum clearances even outside and wall ensure that vegetation and plants also keep to the minimum distances.
REMKO series KWT 5.4 Installation Perform the installation as follows: Cut the required holes out of the mounting template. Fasten the mounting template to the wall. A: Inside Ensure that this is level. Drill the remaining holes for the condensate Mark the required core holes, the fastening drain (min.
Page 15
Install the wall bracket with sufficient screws B: Inside wall to guarantee a secure hold. Suspend the unit on the wall-mounted bracket and check the alignment of the unit. Pay attention to the connection of the con- densate hose and to the electrical power supply.
Page 16
REMKO series KWT Mounting template A: Area for the electrical connection D: Hole for the condensate drainage connection B: Holes for the air inlet and outlet E: Hole for the lift protection bracket C: Holes for the anchors...
5.5 Condensate removal In cooling mode: The unit is equipped with automatic drainage of the condensate water that arises while in cooling mode. For this purpose, the water that arises is collected in the condensate tray of the unit and dis- persed by a pump on the condenser.
Commissioning Before every commissioning the air inlet and outlet openings should be checked for foreign bodies and the air inlet filter must be checked for dirt. Blocked or soiled grills and filters must be cleaned immedi- ately, see "Care and maintenance" chapter. Before starting up, ensure that the power supply is present.
REMKO series KWT Troubleshooting and customer service The unit has been manufactured using state-of-the-art production methods and has been tested several times to ensure that it works properly. If malfunctions should occur, please check the unit as detailed in the list below.
Page 21
Error codes If the unit detects an error, it is shown on the unit display using an error code. In the list below, the individual error codes with the respective cause and possible remedial measures are listed. Repair work may only be carried out by qualified specialist personnel.
REMKO series KWT Care and maintenance Switch the unit off and pull out the power plug. Regular care and observation of some basic points The filter is beneath the upper air intake will ensure trouble-free operation and a long grille. The grille can be pulled out [1] from the service life.
Page 23
In the case of light soiling, clean the filter with Ensure that the filter is dry and undamaged. a vacuum cleaner. NOTICE! Never operate the air conditioner without an original filter. The heat exchanger fins will be contaminated without the filter and the unit will suffer performance loss.
REMKO series KWT Shutdown NOTICE! Never switch off the equipment by pulling out the mains plug. Temporary shutdown If it is planned to shut down the unit for longer periods e.g. during the winter, proceed as follows: Let the unit run in recirculating operation for approx.
Exploded view of the unit and spare parts list 11.1 Exploded view of the unit Fig. 10: Exploded view of the unit - housing KWT 240 DC We reserve the right to modify the dimensions and design as part of the ongoing technical development process.
REMKO series KWT 11.2 Spare parts list IMPORTANT! To ensure the correct delivery of spare parts, please always the device type with the corresponding serial number (see type plate) No. Designation KWT 240 DC Swing fin Swing motor Display bracket...
Page 27
No. Designation KWT 240 DC Evaporator fan motor Control board Combination temperature sensor Air inlet grill Power pcb Housing strut, rear of unit Air filter On request by providing the serial number Evaporator Evaporator condensate tray Air duct internal spigots Air duct plastic sheets Air duct outside panels, set Infrared remote control...