10.17. Press STOP once the PLAY light stops flashing.
10.18. Press TRACK 1 RECORD READY. Verify that its corresponding LEDs are not lit.
10.19. Press TRACK 2 RECORD READY. Verify that its corresponding LEDs are not lit.
10.20. Record the results on the data sheet.

11.0 Tape Offset Test

This test will verify that the BRC can properly setup an offset between the two ADATs and that
both ADATs will play in sync but will be offset by a certain amount of time.
11.1. Press the TAPE OFFSET button. Verify that its LED illuminates.
11.2. Press AUTOPLAY. Verify that its LED is not lit.
11.3. Press LOCATE. Verify that ADAT No. 1 locates to the time input in step 3.1.25 but
ADAT No. 2 is offset by the amount of time input in step 9.3.12.
11.4. Press PLAY. Verify that the PLAY light is lit solid after a few seconds.
11.5. Verify that the LED display on ADAT No. 1 indicates the same time as the BRCs LED
display.
11.6. Verify that the LED display on ADAT No. 2 is offset by the amount of time input in step
9.3.12 and is playing in sync with ADAT No. 1.
11.7. Press STOP.
11.8. Press the TAPE OFFSET button. Verify that its LED is not lit.
11.9. Press LOCATE. Verify that both ADAT LED displays indicate the same time as the BRCs
LED display.
11.10. Press EJECT.
11.11. Record the results on the data sheet.

12.0 Preparation For Delivery

Prepare the BRC for shipping.
12.1. Power off the BRC.
12.2. Re-initialize the BRC by pressing RECORD and PLAY simultaneously while applying
power to the BRC. Verify that the LCD displays the message "Initialization in progress."
12.3. Verify that the PRE-ROLL, POST ROLL, and LOOP LEDs are not lit.
12.4. Record the results on the data sheet.
12.5. Power off the BRC. Remove all connected cables. The BRC is now ready for shipment.
Confidential - Property of Alesis Corporation