<data> - <timecode>
<timecode> - 32-bit timecode transferred as 5 bytes (a=msb, d=lsb)
a7 a6 a5 a4 a3 a2 a1 a0 transfer as 00 a6 a5 a4 a3 a2 a1 a0
b7 b6 b5 b4 b3 b2 b1 b0
c7 c6 c5 c4 c3 c2 c1 c0
d7 d6 d5 d4 d3 d2 d1 d0
03
SMPTE Start Time
<data> --> <hr> <min> <sec> <frm>
<hr> - 0..23, <min> - 0..59, <sec> - 0..59, <frm> - 0..29
04
Pitch
<data> - <deltaH> <deltaL>
<deltaH> - 00000 s bb
<deltaL> - 0 aaaaaaa
05
Sync Type
<data> - <data1> <data2>
<data1> - 0000 baaa
aaa=GenSync MIDI status (0=Off, 1=MIDI clock, 2=MTC)
b=GenSync SMPTE status (0=Off, 1=On)
<data2> - 0000 dcccc
ccc=ExtSync Clock Reference (0=Int, 1=48K, 2=Video, 3=SMPTE)
d=ExtSync Locate Reference (0=Int, 1=SMPTE)
06
Auto Group
<data> - 0=All, 1..8
07
Tape Offset Mode
<data> - 0=time, 1=locate pts, 2=continuous
08
Locate Name
<sub-param> = locate number (1..20)
<data> - <8 ASCII characters>
<ASCII character> - 20H..7AH
09
Locate Address
<sub-param> = locate number (1..22)
<data> - <timecode>
<timecode> - 32-bit timecode transferred as 5 bytes (a=msb, d=lsb)
a7 a6 a5 a4 a3 a2 a1 a0 transfer as 00 a6 a5 a4 a3 a2 a1 a0
b7 b6 b5 b4 b3 b2 b1 b0
c7 c6 c5 c4 c3 c2 c1 c0
d7 d6 d5 d4 d3 d2 d1 d0
0A
Auto Punch-In Locate Num
<data> - 1..22
0B
Auto Punch-Out Locate Num
<data> - 0..22 (0=disable out point)
0C
Loop Start Locate Num
<data> - 1..22
00 b5 b4 b3 b2 b1 b0 a7
00 c4 c3 c2 c1 c0 b7 b6
00 d3 d2 d1 d0 c7 c6 c5
00 00 00 00 d7 d6 d5 d4
s = sign bit (0=pos, 1=neg)
bb = pitch cents <8..7>
aaaaaaa = pitch cents <6..0>
00 b5 b4 b3 b2 b1 b0 a7
00 c4 c3 c2 c1 c0 b7 b6
00 d3 d2 d1 d0 c7 c6 c5
00 00 00 00 d7 d6 d5 d4
21