18. When performing a power-on reset, the display now reads "Initialization in progress."
19. If ADATs are stopped and the tape offset is changed (i.e. whenever tape offset is toggled
on/off or whenever a tape offset value is changed while tape offset is enabled), a locate
command is sent to all ADATs to position them correctly. Note that if ADATs are stopped
with the tape unwrapped when the tape offset is change, all ADATs will wrap the tape when
the locate command is executed.
20. Allow bar mode rollover in tape offset page.
21. Added +/- field to locate pages when in relative normal mode or bars mode (similar to tape
offset counter pages)
22. Send a locate command to ADATs whenever stopping in mode2.
23. Default to Song01 after a tape load.
24. When chasing to external sync, the BRC now sends new "crude locate" commands to the
ADATs and a "normal locate" command when it parks (see ADAT 3.05 software update).
Adding this does not adversely affect functioning of BRC with pre-3.05 software ADATs.
25. Change "Continuous" External Sync option to "Frame Lock" (text change only - Marketing
request)
26. The default pre-roll value was changed from 5 seconds to 8 seconds (Marketing request).
27. If a punch-in is initiated before the auto punch-in point when auto punch is enabled and all
ADATs are not in sync by the time the punch-in point is reached, the display will read "Not
in sync at auto punch-in pt". However, the punch-in will occur when all ADATs become in
sync (as long as it is in-between the auto punch points).
C-6