Accessories; Eliminating Faults - Festo ERMB Series Operating Instructions Manual

Rotary module
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 17
ERMB
10

Accessories

Note
S Please select the appropriate accessories from our catalogue
www.festo.com/catalogue
11

Eliminating faults

Fault
Possible cause
Squeaking
Incorrect controller settings
noises or
vibrations
Rotary module
Loadings too high
does not move
does not move
Fastening screws too long
Motor is blocked
Drive shaft can
Toothed belt fracture
be turned freely
be turned freely
Coupling to motor loosened
Fig. 15
28
Remedy
Modify the controller parameters
Reduce load mass
Reduce positioning speed
Send ERMB to Festo for repairs
Observe maximum screw−in depth
Fitting mechanical components")
Eliminate cause
Send ERMB to Festo for repairs
Check fitting
Tighten clamping screw
(è chapter 5