Raypak RP-045 Installation And Operation Manual

Raypak RP-045 Installation And Operation Manual

Indirect pool heaters
Hide thumbs Also See for RP-045:

Advertisement

Quick Links

INSTALLATION AND
OPERATION MANUAL
Raypak
Indirect
Pool
Heaters
Model Series RP-045 through
RP-995 and B Ti-180 through
B Ti-500
WARNING: If these instructions are not followed exactly, a fire or explosion may
result causing property damage, personal injury or death
FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors and
liquids or other combustible materials in the vicinity of this or any other appliance.
To do so may result in an explosion or fire.
WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency
or the gas supplier.
This manual should be maintained in legible condition and kept adjacent to the heater or in another safe place
for future reference.
.
P/N 241399 Rev. 5
Effective: 04-30-21
Replaces: 12-15-20

Advertisement

Table of Contents
loading

Summary of Contents for Raypak RP-045

  • Page 1 OPERATION MANUAL Raypak Indirect Pool Heaters Model Series RP-045 through RP-995 and B Ti-180 through B Ti-500 WARNING: If these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or death FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors and liquids or other combustible materials in the vicinity of this or any other appliance.
  • Page 2 Rev. 5 reflects the following: Table A: Added "Model Number column". Changed row heading from "CR24" to "Ti". Table C: Added information rows for: RP-185, RP-305 & RP-495.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS 1. WARNINGS ............. 4 Pay Attention to These Terms ......... 4 Caution ..............4 2. WATER CHEMISTRY ..........5 3. INSTALLATION GUIDELINES ......7 Plumbing ..............7 Flow................. 7 Controls ..............8 Chemical feeders or salt water generators ..... 8...
  • Page 4: Warnings

    1. WARNINGS Pay Attention to These Terms Indicates the presence of immediate hazards which will cause severe personal injury, death DANGER or substantial property damage if ignored. Indicates the presence of hazards or unsafe practices which could cause severe personal WARNING injury, death or substantial property damage if ignored.
  • Page 5: Water Chemistry

    2. WATER CHEMISTRY (Corrosive water causes damage that will not be covered under warranty.) For your health and the protection of your pool equipment, it is essential that your water be chemically balanced. The following levels must be used as a guide for balanced water. Recommended Level(s) Fiberglass Pools Fiberglass Spas...
  • Page 6 ** Titanium - widely used in industrial salt water environments. Due to its unsurpassed corrosion resistance, this unique super alloy option is a ‘true’ salt water product, now available from Raypak for the most demanding of applications, from high chlorination to high salt content.
  • Page 7: Installation Guidelines

    Head Loss Surface GPM (L/min) Feet (m) GPM (L/min) Feet (m) SS316L Titanium Ft² (m²) Min. Max. Min. Max. Min. Max. Min. Max. RP-045 (19) (57) (0.2) (0.3) (76) (152) (0.5) (1.8) (0.19) RP-075 (38) (76) (0.3) (0.8) (76) (190) (0.5)
  • Page 8: Controls

    Sample Installation Diagram TO BOILER CONTROL Indirect Pool Heater BOILER WATER FLOW Gate valve Check valve POOL WATER FLOW Flow switch Thermostat or Aquastat Thermometer Drain valve Filter Pool/Spa Pump BOILER WATER FLOW POOL WATER FLOW Bypass valve Union Boiler Pump NOTE: Damage to the Indirect Pool Heater due to improper water chemistry is not covered under the warranty Chlorine feeder must be installed after (downstream of) the Indirect Pool Heater and be installed with an...
  • Page 9 Applicable Warranty Period. In accordance with the terms of this Limited Warranty, Raypak will, at its option, repair or furnish a replacement for any defective part of the HEATER if it fails in normal use and service during the Applicable Warranty Period.
  • Page 10 Warranty is VOID if the product is repaired or altered in any way by ANY persons or agencies other than those authorized by Raypak. Raypak reserves the right at all times to inspect, or require the return of, the defective product or component part and to verify warranty coverage at its factory.
  • Page 11 ISO 9001 REGISTERED QUALITY MANAGEMENT SYSTEM www.raypak.com Raypak, Inc., 2151 Eastman Avenue, Oxnard, CA 93030 (805) 278-5300 Fax (805) 278-5468 Litho in U.S.A.

Table of Contents