3.5

GROUND CONTROL STATION

1
8
7
6
1. Platform/Ground Select Switch
2. Circuit Breaker
3. Emergency Stop Switch
4. Lift/Lower Switch
31215084
SECTION 3 - MACHINE CONTROLS, INDICATORS, AND OPERATION
2
OAD01770
5
4
5. System Fault Indicator
6. Generator Switch (Optional)
7. Overload Indicator (LSS)
8. Hourmeter
3
DO NOT OPERATE FROM GROUND CONTROL STATION WITH PERSONNEL IN
PLATFORM EXCEPT IN AN EMERGENCY.
NOTE: When machine is shut down, the ground control emer-
gency stop switch must be positioned to OFF to prevent
draining the batteries.
1.
Power/Emergency Stop - A two-position red mush-
room shaped switch furnishes power to Platform/
Ground Select switch when pulled out (on). When
pushed in (off), power is shut off to the Platform/
Ground Select switch.
2.
Platform/Ground Select - A three position, key oper-
ated switch supplies power to platform control con-
sole when positioned to platform. With the key held in
the ground position, power is shut off to platform and
only ground controls are operable.
NOTE: With Platform/Ground Select in center position, power is
shut off to controls at both operating stations.