Samson 2780-1 Mounting And Operating Instructions page 34

Pneumatic actuators
Table of Contents

Advertisement

Servicing and conversion work
phragm (A48) and metal plate (A38) in‑
to the bottom diaphragm case (A40).
8. Tighten the collar nut (A53).
9. Place the springs (A25) in the bottom di‑
aphragm case (A40), centering them in
the intended recesses.
10. Place on the top diaphragm case (A42).
11. Fasten the top and bottom diaphragm
cases (A42, A40) together with the nuts
and bolts.
b) Version with direction of
action "actuator stem
retracts"
1. Lift off the top diaphragm case (A42).
2. Unscrew the collar nut (A53).
A42
A53
A40
A23
Actuator stem extends
Fig. 8-1: Type 2780‑1
8-4
A38 A39
A25
A1
Actuator stem retracts
3. Remove the diaphragm plate (A39) to‑
gether with the diaphragm (A48), metal
plate (A38) and actuator stem (A1) out
of the bottom diaphragm case (A40).
4. Place a new diaphragm on the metal
plate (A38). Place on the diaphragm
plate (A39).
5. Check the sealing element on the collar
nut (A53). If necessary, renew it.
6. Apply a suitable sealant and lubricant to
the actuator stem (A1).
7. Insert the actuator stem (A1) together
with the diaphragm plate (A39), dia‑
phragm (A48) and metal plate (A38) in‑
to the bottom diaphragm case (A40).
8. Tighten the collar nut (A53).
9. Place on the top diaphragm case (A42).
A1
Actuator stem
A20
Vent plug
S
A23
Coupling nut
FE
A25
Compression spring
A48
A38
Metal plate
A39
Diaphragm plate
A20
A40
Bottom diaphragm case
A42
Top diaphragm case
S
FA
A48
Diaphragm
A53
Collar nut
S
Signal pressure connection
FA
(actuator stem extends)
S
Signal pressure connection
FE
(actuator stem retracts)
EB 5840 EN

Advertisement

Table of Contents
loading

This manual is also suitable for:

2780-2

Table of Contents