Technical Data; Electrical Data - Kaco blueplanet 87.0 TL3 M1 WM OD IIF0 Operating Instruction

Hide thumbs Also See for blueplanet 87.0 TL3 M1 WM OD IIF0:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
4

Technical data

4.1

Electrical data

Recommended generator
power range
MPPrange@Pnom
Working range
Rated voltage
Starting voltage
2
Open circuit voltage
3
Max. input current
Number of strings
Number of MPP controls
Max. short-circuit current (ISC
max.)
Input source feedback current
Polarity safeguard
String fuse
DC overvoltage protection
AC Output levels
Nominal power
Rated voltage
Voltage range: continuous
operation
Rated current
Max. continuous current
Contribution to peak short-
circuit current ip
2
A brief open circuit voltage of up to 1600 V
Due to the brief open circuit voltage exceedance, there is no guarantee that the integrated overvoltage protection
will work correctly if the ambient temperature is > 40°C.
3
The "Max. input current" is the maximal theoretical value during operation at full power and minimal MPP voltage.
The inverter will clip to the maximum AC power output.
The "Max. short-circuit current (ISCmax.)" defines together with open circuit voltage (Uocmax) the characteristic of
the connected PV generator. This is the relevant value for string sizing and is the absolute maximal limit for inverter
protection. The connected PV-Generator must be designed, that the max short circuit current is below or equal to IS-
Cmax of the inverter under all foreseeable conditions. In no condition the design may result in a greater short circuit
current than ISCmax of the inverter.Configuring the PV generator [See section 7.6.2} Page 22].
KACO blueplanet 87.0 TL3 KACO blueplanet 92.0 TL3 KACO blueplanet 110 TL3 KACO blueplanet 125 TL3
KACO blueplanet 137 TL3 KACO blueplanet 150 TL3
KACO blue-
KACO blue-
planet 87.0
planet 92.0
TL3 M1 WM
TL3 M1 WM
OD IIF0
OD IIG0
130.5 kW
138 kW
563 V - 1300
591 V-1300 V 705 V-1300 V 875 V-1300 V
V
563 V - 1450
591 V-1450 V 705 V-1450 V 875 V-1450 V 875 V -1450 V 960 V-1450 V
V
600 V
620 V
645 V
675 V
KACO blue-
KACO blue-
planet 87.0
planet 92.0
TL3 M1 WM
TL3 M1 WM
OD IIF0
OD IIG0
87 kVA
92 kVA
380 V (3P+PE) 400 V (3P+PE) 480 V (3P+PE)
300 V - 437 V 300 V - 460 V 300 V - 552 V
3 x 132.3 A
3 x 132.3 A
(max. 15 hours a year) is admissible for the device.
dc
KACO blue-
KACO blue-
planet 110
planet 125
TL3 M1 WM
TL3 M1 WM
OD IIK0
OD IIP0
165 kW
187.5 kW
730 V
900 V
805 V
1000 V
1500 V
160 A
1-2
1
300 A
0 A
no
no
Yes
KACO blue-
KACO blue-
planet 110
planet 125
TL3 M1 WM
TL3 M1 WM
OD IIK0
OD IIP0
Output levels (AC)
110 kVA
125 kVA
600 V [3P+PE]
480 V - 690 V
3 x 132.3 A
3 x 120.3 A
3 x 132.3 A
193 A
KACO blue-
KACO blue-
planet 137
planet 150
TL3 M1 WM
TL3 M1 WM
OD IIP0
OD IIQ0
205.5 kW
225 kW
875 V -1,300
960 V-1300 V
V
1000 V
1100 V
KACO blue-
KACO blue-
planet 137
planet 150
TL3 M1 WM
TL3 M1 WM
OD IIP0
OD IIQ0
137 kVA
150 kVA
660 V (3P+PE)
480 V - 760 V
3 x 132.3 A
3 x 131.2 A
Page 11