Receptacle
wiring
Use 14 gauge (minimum) wire for receptacle wiring. Use
copper wire only. It is the responsibility
of the consumer to
provide proper and adequate receptacle wiring, installed by a
qualified electrician. Observe the National Electrical Code and
all local governing codes and ordinances.
Electrical
requirements
A 115 Volt (103.5 min., 126.5 max.), 60 Hz. AC only, 15
ampere fused electrical supply is required. Use a time-delay
fuse or circuit breaker. It is required
that a separate circuit.
serving only this appliance, be provided.
Electrical
connection
Electrical ground is required on this appliance.
Alambrado
del
tomacorriente
El alambrado del tomacorriente
tiene que ser de calibre 14
coma minimo. Usar alambre de cobre solamente.
Es la
responsabilidad
del consumidor proveer alambrado del
tomacorriente
adecuado y apropiado, instalado por un
electricista calificado. Cumplir el Codigo National de
Electricidad y todos 10s codigos y reglamentos
locales
vigentes.
Requerimientos
elhctricos
Se requiere un siministro electrico con fusible de 115 voltios
(103.5 min., 126.5 max.), 60 Hz, CA de 15 amperios solamete.
Usar un fusible de action retardada o disyuntor de action
retardada. Se requiere
que se provea un circuit0 separado
para ser usado por este artefacto solamente.
Conexih
ektrica
Este ar-tefacto debe ser puesto a tierra.