Analysis Menu - E Instruments E4500 Operating & Maintenance Manual

Combustion analyzer
Hide thumbs Also See for E4500:
Table of Contents

Advertisement

9.2
Configuration→Analysis
07/08/14
10:00
Configuration
Analysis
Fuel
Condensation
O
reference
NO
/NO ratio
2
x
Measure units
Autozero
Measures list
PARAMETER
Lets the user select the type of fuel to be used during analysis. This data can be varied either
from this menu or during the analysis itself.
By selecting the sub menu Fuel coefficients the user can view the characteristics of the fuels
Fuel
used in the calculation of performance. SEE SECTION 9.2.1.
The burner efficiency figure when condensation takes place is influenced by atmospheric
pressure and humidity of the combustion air. As the atmospheric pressure is hardly precisely
known, the operator is asked to enter a related parameter, i.e. the altitude of the place above the
sea level, from which the pressure is then derived once the dependency from atmospheric
conditions is neglected. In calculations the value of 101325 Pa is assumed as atmospheric
Condensation
pressure at sea level. Further the air relative humidity input is allowed, being this calculated at
the combustion air temperature as measured from the instrument; in case this value is unknown
the operator is recommended to enter 50% for this value.
SEE SECTION 9.2.2.
In this mode the user can set the oxygen percentage level to which pollutant emission values
detected during analysis will be referenced.
SEE SECTION 9.2.3.
O
reference
2
NOx/NO: all the nitrogen oxides which are present in the flue emissions (Nitrogen oxide = NO,
Nitrogen dioxide = NO
In the combustion processes, it is found out that the NO
far from very low values (3%); hence it is possible to obtain the NOx value by a simple
calculation without using a direct measurement with a further NO
NO
/NO ratio
The NO
x
(default value).
SEE SECTION 9.2.4.
Through this submenu the user can modify the units of measurement for all the analysis
parameters, depending on how they are used.
SEE SECTION 9.2.5.
Measure units
In this sub menu the user can change the length of the autozero cycle of the analyzer and start it
manually.
SEE SECTION 9.2.6.
Autozero
In this sub menu the user can see the list of measurements that the device can perform. With
the interactive keys, the user can add, delete or move a selected measurement.
SEE SECTION 9.2.7.
Measures list
CONTEXT KEY
); total nitrogen oxides = NOx (NO + NO
2
percentage value contained in the gas can be however set at a value other than 3%
2
KEY
FUNCTION
Activate the context keys shown on the
display.
Returns to the previous screen.
FUNCTION
Selects the available parameters.
OK
Enters in the selected parameter setting.
Selects the available parameters.
DESCRIPTION
2
25
).
2
percentage contained in the gas is not
sensor.
2
K000000000EJ 023826A0 100714