VT-BB501 Blackbody Installation with Tripod
1. Align the holes of the blackbody with the holes of the adapter as shown below. Then fasten
the blackbody to the adapter with screws.
2. Screw the adapter with the black body onto the tripod (sold separately from blackbody).
Installation and Use Requirements
- In order to ensure accuracy in temp. measurement, the recomended ambient temp. is
50~95°F (10~35°C), and the infrared light should be turned off during temp. measurement.
- The VTC-TNB5TH can be used independently, but will provide greater accuracy when used
with the blackbody callibration device, VT-BB501 (sold separately).
- The VTC-TNB5TH should be used in a stable, wind-free indoor environment. Make sure the
monitoring field is far away from any objects that could produce airflow, high temp. or reflection.
- Avoid installation near a door or an air conditioner, or any place in direct sunshine.
- The recommended monitoring distance is 2~6m 6'7"~19'8". To monitor an aisle, the best
temperature measurement distance is 6'7"~13'9" (2~4M).
- Set up a 1-way temp. measuring zone and make sure the camera can clearly see subjects'
faces.
- The VTC-TNB5TH requires 20-30 minutes after powering up to give steady readings.
- It is recommended to use DC 12V power supply to reduce power consumption.
- If the VT-BB501 is used with the camera, it should be installed 6'7"~9'9" (2-3M) away from
the camera. It cannot be blocked. During operation, do not move the camera or black body
callibration device, and make sure the VT-BB501 is positioned in a proper place within
the camera image.
(See Diagram on Next Page)