Lincoln Electric FLEXCUT 125 CE Safety Instruction For Use And Maintenance page 35

Table of Contents

Advertisement

8695 4496 / B
2.4
Other faults
Fault
The tool-holder does not move
Two torches cannot be selected
Cutting cannot be started
Cutting is not correct
Incorrect cutting height
FLEXCUT 125 CE INSTALLATION
Probable causes
The torch has not been selected
Lower limit switch (UI alarm)
Probe impact (UI alarm)
Upper limit switch (no alarm)
The two torches are not identical
(type)
Lack of extraction or ineffective
extraction
Several possible causes.
The tool holder speed offset has
not been set.
The plate is not on fixed supports
F - MAINTENANCE
Possible remedies
Select the torch manually
Correct the fault and set the tool
holder position if required.
Correct the fault and clear the
alarm
Correct the fault and set the tool
holder position if required.
Select two identical torches
Start/clean the extraction before
cutting
Refer to the process training
manual
Set the speed offset of the
variable speed drive
Reposition the plate or change
the detection method (using pilot
arc)
F-31

Advertisement

Table of Contents
loading

Table of Contents