User Guide | ERC 112D VSC Refrigeration Controller
Code numbers
Sx (di)= connector position.
Inputs are configurable.
8 | BC286552322855en-000201
Type
ERC 112D VSC, Blue LED, with
buzzer
Temperature sensors
-40 – 80 °C, PVC Standard, NTC 5 K
S1, 470 mm, 3-pole
S1, 1000 mm, 3-pole
S1, 1500 mm, 3-pole
S1, 2000 mm, 3-pole
S1, 2200 mm, 3-pole
S1, 3000 mm, 3-pole
S1, 3500 mm, 3-pole
S1, 6000 mm, 3-pole
-40 – 120 °C, TPE precision NTC 5 K, Santroprene
S1, 1500 mm, 3-pole
S1, 2000 mm, 3-pole
-20 – 200 °C, Silicone rubber cable, NTC 100 K
S1/S3, 2000 mm, 3-pole
-40 – 80 °C, PVC Standard, NTC 5 K
S2, 1000 mm, 2-pole
S2, 1500 mm, 2-pole
S2, 2000 mm, 2-pole
S2, 3000 mm, 2-pole
S2, 6000 mm, 2-pole
S3, 1000 mm, 3-pole
S3, 1500 mm, 3-pole
S3, 2200 mm, 3-pole
S3, 3000 mm, 3-pole
S3, 6000 mm, 3-pole
I-Pack
Type
Qty.
Code no.
27
080G3414
Light-sensors
S3, 1000 mm, 3-pole
S3, 2000 mm, 3-pole
S3, 3000 mm, 3-pole
120
077F8751
Cable, variable speed compressor
120
077F8757
S4, 3500 mm, 3-pole
120
077F8761
Magnetic door sensor
120
077F8765
di, 1000 mm, 3-pole
077F8767
120
di, 2000 mm, 3-pole
60
077F8769
di, 3000 mm, 3-pole
60
077F8723
27
080G2019
Cable door sensor
di, 1000 mm, 3-pole
120
077F8726
di, 2000 mm, 3-pole
120
077F8727
di, 3000 mm, 3-pole
di, 4000 mm, 3-pole
108
080G2043
Motion sensor
120
077F8786
S3/di, 3000 mm, 3-pole
120
077F8790
Clips
120
077F8794
Black (2 needed per controller)
60
077F8798
080G2029
27
Programming
120
077F8756
OEM Docking station, production
120
077F8760
line
077F8766
Gateway incl USB Cable, R&D
120
Programming key EKA183A
60
077F8768
27
080G2039
Power plug *
6-pole with screw
* The connectors are rated for 28 Amps max.
Note: For more information about temperature sensor
types and connectors, please refer to Danfoss' technical
brochure "NTC type temperature sensors for ETC & ERC
controllers".
I-Pack
Qty.
Code no.
108
080G3311
108
080G3313
108
080G3315
81
080G3397
81
080G3320
080G3322
81
080G3324
81
108
080G3340
108
080G3341
108
080G3342
81
080G3343
27
080G3392
080G3308
54
080G9701
1
1
080G9711
1
080G9740
54
080G3357
© Danfoss | DCS (vt) | 2019.07
Need help?
Do you have a question about the ERC 112D VSC and is the answer not in the manual?
Questions and answers
What does 4.5.6 connect to ?
Mostrador do controlar, fica travado , não mostra a temperatura real
The Danfoss ERC 112D VSC display may be stuck and not showing the actual temperature due to the "rLt" (Display Range Limit) parameter being set to restrict the displayed temperature to the cut-in / cut-out limits instead of the actual temperature. If "rLt" is set to "yes," it will not show the real temperature. To display the actual temperature, "rLt" must be set to "nO".
Additionally, the display might update slowly if a "ddL" (Display Delay) is set, causing a delay in showing temperature changes. Also, temperature updates can be blocked during fan OFF periods and only resume after the fan has been running for a while.
This answer is automatically generated
como entrar no parâmetro "rLt" (Limite da Faixa de Exibição) e fazer alteração?
To access and change the "rLt" (Display Range Limit) parameter on the Danfoss ERC 112D VSC, follow these steps:
1. Enter the parameter configuration mode.
2. Navigate through the parameter list to find "rLt".
3. Select "rLt" to view or change its value.
4. Set the value to “nO” to display the actual temperature or “yes” to restrict the display to cut-in/cut-out limits.
5. Confirm the selection to save the change.
The default setting is “nO”.
This answer is automatically generated