Installation

DANGER! Read "Safety information" on page 3 before attempting to
install this product.
The safety and suitability of lifting equipment, installation location,
anchoring method, mounting hardware and electrical circuits are the
responsibility of the installer. All local safety regulations and legal
requirements must be observed when installing and connecting the
Cyclo IP65 Directional. Installation must be carried out by qualified
professionals only.
This section describes how to install the luminaire, including how to connect
it to power and control data cables, and how to set it up for DMX control or
stand-alone operation.
We recommend that you read the Installation section of this manual and
familiarize yourself with the procedures involved before starting to install
luminaires. If you are not familiar with DMX, pay particular attention to the
section on setting DMX addresses.
I n c l u d e d i t e m s
Cyclo IP65 Directional luminaires are supplied with the following items:
• Osram T5 fluorescent tubes (installed)
• Surface-mounting bracket.
• Two TET 5-7 Thorsman rubber membrane cable glands (installed) for
data cable entry: cable diameter 5-7 mm (0.20-0.28 in.)
• Two TET 10-14 Thorsman rubber membrane cable glands (installed) for
power cable entry: cable diameter 10-14 mm (0.40-0.55 in.)
• Two M25 metal blanking plugs (installed) for unused power cable entry
holes.
• Two M16 metal blanking plugs (installed) for unused data cable entry
holes.
• Two M25 metal IP68 cable glands (supplied loose) for AC power cable
entry: cable diameter 7 - 15 mm (0.28 - 0.6 in.).
• Two M16 metal IP68 cable glands (supplied loose) for data cable entry:
cable diameter 5 - 12 mm (0.2 - 0.45 in.).