Refer any operation not described in this manual to a qualified technician. If you have any questions about how to operate this luminaire safely, contact your Martin Architectural supplier or call the Martin 24-hour service hotline on +45 70 200 201. Protection from electric shock •...
Page 4
• Do not expose the luminaire to a high-pressure water jet. • Do not immerse the luminaire in water or install it in a location where flooding may occur. • Refer all service not described in this manual to a Martin service technician. Protection from burns and fire •...
Introduction ® Thank you for selecting a luminaire from the Martin Architectural Cyclo IP65 Directional series. Cyclo IP65 Directional luminaires are fluorescent tube-based dynamic color-changing luminaires designed for illumination of walls and surfaces. Dimmable 54 watt T5 fluorescent tubes combine high efficiency, bright color and long lamp life.
Installation DANGER! Read “Safety information” on page 3 before attempting to install this product. The safety and suitability of lifting equipment, installation location, anchoring method, mounting hardware and electrical circuits are the responsibility of the installer. All local safety regulations and legal requirements must be observed when installing and connecting the Cyclo IP65 Directional.
(A) so that it clips down over the cover. The seals on the inside faces of covers must be in perfect condition to maintain their waterproof qualities. Avoid damaging them. Any seal that is not in perfect condition must be replaced by a Martin service agent. Installation...
Avoid damaging them. Any seal that is not in perfect condition must be replaced by a Martin service agent. 4. Tighten the two screws at either end of the cover before applying power.
M o u n t i n g DANGER! It is the installer’s responsibility to ensure that the installation is safe and that all local safety regulations and legal requirements are observed when mounting the Cyclo IP65 Directional. The Cyclo IP65 Directional can be surface-mounted on a floor, wall or ceiling.
the T-section (C) on the upper side of the base passes behind the retaining rail (D). 6. Tighten the retaining screws (E) so that the retaining rail (D) grips the T- section (C) tightly. Check that the luminaire is held securely. O r i e n t a t i o n a n d a d j u s t m e n t Important! The Cyclo IP65 Directional support arms must both be fixed at the same angle.
Page 13
Adjust ing the support arm angle To adjust the angle of the support arms in the base module: 1. Ensure that the luminaire is securely mounted and isolated from power. 2. Open the connections compartment as described in “Access to connections compartment”...
Page 14
Adjust ing the tube module t ilt angle To rotate the tube module in the support arms: 1. Ensure that the luminaire is securely mounted and isolated from power. 1. Open the front cover as described in “Access to tube module” on page 9. 2.
“Included items” on page 8, new cable glands that match cable diameter must be obtained from Martin or an electrical supplier. • Rubber and metal glands must be replaced with new items if cable in an existing installation is replaced with cable of a different diameter.
Page 16
Replacement metal glands must have the following characteristics: Temperature range: ....-20° to +70°C or better Ingress protection rating: ..... . . IP67 or IP68 Power cable gland thread size: .
Page 17
2. See Figure 10. Dismantle the cable gland. A – O-ring seal B – Cable entry C – Gland D – Washer E – Compression nut : Metal cable gland Figure 10 3. Ensure that there is a rubber O-ring A on the housing end of the cable entry B, and screw this end into the threaded hole in the housing.
A C p o w e r DANGER! It is the installer’s responsibility to ensure that all power cable and equipment is adequately dimensioned and of appropriate type for the installation, and that all local safety regulations and legal requirements are observed when installing and connecting the Cyclo IP65 Directional.
Page 19
permitted RCD trip current ratings are normally stated in national electrical and building codes. 3. Install surge current-resistant RCDs. Connecting to power A screw clamp is provided for connecting the luminaire to the power cable’s earth conductor, and a block of spring-loaded clamp terminals are provided for connecting the luminaire to the power cable’s live and neutral power conductors.Some common color-coding systems for power wiring are given below:...
Page 20
5. Connect the Power terminals DMX terminals conductors in the power input cable as follows: • Connect the Shield Shield ground (earth) wire to the screw terminal marked close to the power terminals. • Connect the neutral wire to the spring-loaded power terminal marked N...
90758060) must be used. A male 3-pin XLR connector can be fitted at the controller end of the data link to allow a standard connection to Martin DMX controller. The XLR connector should be wired as follows: • Pin 1: shield •...
Page 22
Connecting to control data DMX controller Master Slave Slave 120 Ohm resistor 120 Ohm resistor DMX control link Master/slave link To create the data link: 1. If using a DMX control device, run suitable cable from the controller’s DMX output to the first luminaire on the link. 2.
Page 23
Co nfiguring luminai res for DMX or stand-alone operat ion Each DMX model Cyclo IP65 Directional luminaire needs to be set up for DMX or stand-alone operation using the DIP switch located on the circuit board in the base module. 1 2 3 5 6 7 8 910 Figure 12: DIP switch...
Page 24
Martin Address Calculator at http://www.martin.dk/service/utilities/AddrCalc/index.asp (see illustration below). 3. You can also look up DIP switch settings using the Martin DIP Switch Calculator, available for use and downloadable at http://www.martin.dk/service/dipswitchpopup.htm If you do not have Internet access, refer to "Table 2: DMX address DIP switch settings"...
Page 25
To use this table, first find the DMX address in the main block in the table. Then read the settings for pins 1 - 5 to the left and read the settings for pins 6 - 9 above the address. “0” means OFF and “1” means ON. For example, to set the DMX address to 101, you need to set DIP switch pins 1, 3, 6 and 7 to ON, as highlighted in the table.
Page 26
C o n f i g u r i n g f o r s t a n d - a l o n e o p e r a t i o n Stand-alone operation is enabled by setting pin 10 on the DIP switch to ON and pin 8 to OFF.
To optimize tube life in stand-alone mode, program color-changing cycles that run as slowly as possible. For more detailed information on maximizing tube lifetimes, see the Martin website at http://www.martin.com/service. Achieve optimum tube performance by ‘burning in’ new fluorescent tubes, i.e.
or two with the front cover removed so that air circulates, then refit the front cover while the luminaire is hot. If you do this: • The exposed internal components present a risk:, so block public access. • Ensure that no dust or objects enter the luminaire while it is open. O p e r a t i o n i n e x t r e m e a m b i e n t t e m p e r a t u r e s Do not operate the Cyclo IP65 Directional if the ambient temperature...
Stand-alone operation DANGER! Read “Safety information” on page 3 before attempting to operate this product! In stand-alone operation, the Cyclo IP65 Directional can run light shows without a DMX controller. Luminaires can be programmed to change colors in cycles. Changes can be programmed at 1, 5, 10 or 30 second intervals. Two stand-alone operation modes are available: •...
A quick reference table covering DIP switch functions is also provided on the back cover of this manual. S t a n d - a l o n e o p e r a t i o n s e t t i n g s Acti vating t ubes DIP switch pins 1 to 3 (03 models) or 1 to 4 (04 models) activate tubes in the stand-alone program.
S i n g l e s t a n d - a l o n e o p e r a t i o n In single stand-alone operation, a luminaire runs its own program independently of all other luminaires. To do this, the luminaire must be set as a master.
Page 32
Consult your Martin Architectural supplier if you need advice on combining and controlling products. Identical light shows Master and slave luminaires can be set to behave identically. In this mode, the master sends synchronizing signals to the slaves, and all luminaires run the same light show.
Page 33
Program exa mples The following examples of programs show how an individual luminaire’s program is made up of scenes. The following symbols are used in program diagrams: Tube turned fully off Fade in Fade out Fade to 50% and back to 100% in one scene (applies when only one color is active and crossfading is selected) Exa mple 1...
Page 34
Example 4 DIP switch 7 is set to OFF (blackout fading) and red and blue are activated: Blue Scene Example 5 To achieve a rainbow effect, activate red, green and blue tubes and set DIP switch pin 7 to ON (crossfading). Green Blue Scene...
See the controller’s manual for details. Your Martin Architectural supplier can advise about available controllers and control options. DMX-controlled operation...
Refer any service operation not described in this manual to an authorized Martin service agent. C l e a n i n g Use a damp cloth or soft brush soaked in a solution of water and a mild detergent cleaner such as auto shampoo to clean luminaires.
Page 37
3. See Figure 13. Remove the reflector by lifting it out of the tube module housing. 4. In 04 models, remove the white tube by holding the metal caps at both ends of Figure 13: Removing the reflector the tube, rotating the tube approx.
Page 38
7. When installing new tubes, line them up so that the manufacturer’s markings on all tubes are at the same end of the luminaire. Tube positions are labelled R for red, G for green and B for blue. Slide each tube’s terminal pins fully into their sockets and rotate the tube approx.
M ai n fu s e r e p l ac e me nt The main fuse is located on the PCB in the ballast tray. See page 43 in the Specifications section for details of fuse types and ratings. Never replace a fuse with one of a different type or rating.
230V 115V Figure 16: Main fuse 5. Reinstall all covers before reapplying power. If a fuse blows repeatedly, refer to your Martin Architectural supplier for service. V o l ta g e s e tt in g See Figure 16. The voltage switch on the PCB is factory-set to match 100-120 or 200-240 V nominal AC power at 50 or 60 Hz.
Bypass luminaires one at a time until normal operation is regained to identify faulty luminaire. Have faulty luminaire tested and repaired by Martin service technician. Two luminaires transmitting on Check that only one luminaire link. is set to operate as master.
Cyclo IP65 Directional specifications Physical L x W x H ....1257 x 149 x 230 mm (49.5 x 5.9 x 9.1 in.) Weight ........22 kg (48.5 lbs) Lamp Type .
Page 44
Electrical AC power ....100-120/200-240 V nominal, 50/60 Hz Main fuse, 03, 120 V model ..... . . 2 AT (slow blow) Main fuse, 04, 120 V model .
Page 45
Included items Osram FQ 54 W/60 HO red T5 tube Osram FQ 54 W/66 HO green T5 tube Osram FQ 54 W/67 HO blue T5 tube Osram FQ 54 W/840 HO cool daylight white (4000 K) T5 tube (04 models) Two M25 cable glands, IP68, metal, cable Ø...
Page 46
Electronic Equipment), as amended by Directive 2003/108/EC, where applicable. Help preserve the environment! Ensure that this product is recycled at the end of its life. Your supplier can give details of ® local arrangements for the disposal of Martin products.
Need help?
Do you have a question about the Cyclo Directional IP65 and is the answer not in the manual?
Questions and answers