Martin Cyclo Directional IP65 User Manual page 19

Table of Contents

Advertisement

permitted RCD trip current ratings are normally stated in national
electrical and building codes.
3. Install surge current-resistant RCDs.
Connecting to power
A screw clamp is provided for connecting the luminaire to the power cable's
earth conductor, and a block of spring-loaded clamp terminals are provided
for connecting the luminaire to the power cable's live and neutral power
conductors.Some common color-coding systems for power wiring are given
below:
Wire (EU)
Wire (US)
brown
blue
yellow/green
Table 1: Power cable color-coding systems
To connect to AC power:
1. Ensure that power cannot be applied to the cable during installation.
2. Open the connections compartment as described in "Access to
connections compartment" on page 10.
3. Pass the power input cable through a cable gland as described in "Cable
entry" on page 15 so that approximately 20 cm (8 in.) of cable is free
inside the luminaire, and prepare the end of the cable for connection.
4. See Figure 11. Four spring-loaded terminals marked L1, L2, L3 and N
and one screw clamp marked
connection. The terminals marked L2 and L3 are not used to supply
power to the luminaire and are provided only to allow phase conductors
to be connected if power is supplied from a 3-phase system (see
"Connecting to a 3-phase system" on page 20).
Pin
black
live
white
neutral
green
ground
are provided for power cable
Installation
Marking on luminaire
L1
N
19