CapTouch Cabin Control
4 .2 Cable Length
Display Cable
Self-Contained
Inside Air Temperature
Sensor (optional)
OAT Sensor (optional)
All custom cable lengths
are supplied in standard
5 ft (1 .5 m) increments
4 .3 Available System Inputs
Water Inlet
Temperature Sensor
(CW Installations Only)
High Refrigerant Pressure
Inside Air Temperature
Sensor (optional)
Low Refrigerant Pressure
(optional)
OAT Sensor (optional)
Pump Sentry Water
Sensor (optional)
(DX Installations Only)
Room Temperature/
Relative Humidity
Combination Sensor
(optional)
EN
15.0 ft (4.6 m) Standard
7.0 ft (2.1 m) Standard
15.0 ft (4.6 m) Standard
75.0 ft (22.9 m) Maximum
1
1
1
1
1
1
1
4 .4 Operational Specifications
Set Point Operating
Range
Ambient Temperature
Operating Range
Displayed
Sensor Accuracy
Low Voltage Limit
100–120 V
Low Voltage Limit
200–240 V
Low Voltage Processor
Reset
Universal Line Voltage
Frequency
Fan Output
Valve Output
For CW Only:
Auxiliary Electric
Heater Output
(using compressor
output L1 and L2)
External Triac
External Q-Relay
Pump Output
Compressor Output
Minimum Operating
Temperature
Maximum Ambient
Operating Temperature
Maximum Rh Conditions
Power Consumption
Specifications
55 °F to 99 °F (13 °C to 37 °C)
5 °F to 150 °F (-15 °C to 66 °C)
± 2 °F @ 77 °F (±1 °C @ 25 °C)
95 VAC
195 VAC
50 VAC
100–240 VAC
50 Hz or 60 Hz
6 A @ 115 VAC
6 A @ 230 VAC
5 A @ 115/230 VAC
30 A Maximum
26 A
30 A Maximum
1/4 HP @ 115 VAC
1/2 HP @ 230 VAC
1 HP @ 115 VAC
2 HP @ 230 VAC
0 °F (-18 °C)
180 °F (82 °C)
99% Non-condensing
< 5 W
5