Set Point Operating Range. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65°F to 85°F (18.3°C to 29.4°C)
Ambient Temperature Operating Range Displayed . . . . . . . . . . . . . . 5°F to 150°F (-15°C to 65.6°C)
Sensor Accuracy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .± 2°F @ 77°F (±1.1°C @ 25°C)
Low Voltage Limit 115 Volt Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .75 VAC
Low Voltage Limit 220 Volt Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .175 VAC
Low Voltage Processor Reset. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50 VAC
Line Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115 Through 240 VAC
Frequency. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 or 60 Hz
Fan Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Amps @ 115 VAC
Fan Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Amps @ 230 VAC
Valve Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/4 Amp @ 115/230 VAC
For circuit boards revision F and newer:
Heater Output (using compressor relay) . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Amps @ 115 VAC
Heater Output (using compressor relay) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Amps @ 230 V
For circuit boards revision E and older:
Heater Output (using heater relay) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Amps @ 115 VAC
Heater Output (using heater relay) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Amps @ 230 V
D
IMENSIONS
Compact model - Display Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.19" (82mm) X 2.5" (64mm)
Compact model - Panel Cut Out . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.4" (61mm) X 1.8" (46mm)
Legacy model - Display Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . 4.5" (114mm) X 3.86" (98mm) high
Legacy model - Panel Cutout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.375" (86mm) X 2.875" (73mm)
C
L
ABLE
ENGTHS
Display Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15' (4.6m) Standard
Alternate Air Sensor (optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7' (2.1m) Standard
Outside Air Sensor (optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15' (4.6m) Standard
All custom cable lengths supplied in standard 5' (1.5m) increments . . . . . . . . 75' (22.9m) Maximum
NOTE
Maximum length of display and sensor cables is 75 feet (22.9m). The outside-air sensor and alternate air sensor are
optional items and are not included with the standard control package.
S
I
YSTEM
NPUTS
Ambient or Inside-Air Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Water Inlet Temperature Sensor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Alternate Inside-Air Temperature Sensor (optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Outside-Air Temperature Sensor (optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

WARRANTY AGREEMENT

This control may be covered under Dometic's Unit Warranty or Dometic's Part Warranty. Please refer to the specific warranty
data sheet for more information.
14
AH-Passport I/O Control Operations Manual
L-2232 ENGLISH

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ah-passport i/o

Table of Contents