Wi-Fi Connectivity; Seawater Low-Limit Adjustment; Humidity Sensor Calibration; Water Inlet Temperature Sensor Calibration - Dometic CapTouch Installation And Operating Manual

Marine control units
Table of Contents

Advertisement

CapTouch Cabin Control
Parameter
Name
P-30

Wi-Fi Connectivity

Seawater Low-Limit
P-31
Adjustment
Humidity Sensor
P-32
Calibration
Water Inlet Temperature
P-33
Sensor Calibration
P-34

OAT Sensor Calibration

7 .4 .3 Exiting programming mode
To exit the programming menu manually, simultaneously
tap and hold the Up (+) and Mode icons for three
seconds until the room temperature is displayed.
Alternatively, the display automatically exits the
programming menu after 10 seconds of inactivity.
The control's software version (such as "40") appears
in the display for one second prior to the manual or
automatic exit from the programming mode. The control
enters OFF mode after exit.
EN
DX
CW
Factory Default
x
x
DIS
Available only in Wi-Fi capable displays, indicated by the Wi-Fi icon on the display. Refer to "Using the
CapTouch Wi-Fi Application" on page 21 for detail on the full functionality of the Wi-Fi capability.
x
40 °F (4 °C)
If the optional seawater low-limit adjustment sensor is connected to the control board H2O Out 2-pin
plug, set the system to switch from reverse-cycle heat to auxiliary electric heat (if an auxiliary electric
heater is installed and enabled).
• Adjustment occurs when the seawater temperature drops below 40 °F (4 °C) and the reverse-cycle
heat has been in operation for more than five minutes. Once the seawater rises 3 °F above the
seawater low-limit adjustment sensor temperature set point, the system returns to reverse-cycle
heating.
• If an auxiliary electric heater is not installed, the system will shut down and flash LO then SE when the
seawater drops below 40 °F (4 °C) (default). Once the seawater rises 3 °F above the seawater low-
limit adjustment sensor temperature set point, the system automatically goes back into reverse-cycle
heating and stops flashing LO then SE.
Ambient Relative
x
x
Humidity
Calibrate the room temperature/relative humidity combination sensor to display the correct room
humidity reading.
I
This setting is applicable to software revision #42 and newer only.
CW = Supplied
Chilled Water
Temperature
x
x
DX = Condenser Coil
or Seawater
Temperature
Calibrate the Water Out (DX) or Water In (CW) temperature sensor to display the correct water
temperature reading. The setting increments are in °F even when the control is set to display °C.
I
This setting is applicable to software revision #42 and newer only.
Outside Ambient
x
x
Temperature
Calibrate the outside ambient air temperature sensor to display the correct outside air temperature
reading. The setting increments are in °F even when the control is set to display °C.
I
This setting is applicable to software revision #42 and newer only.
Parameter Range
35 °F to 50 °F (2 °C to 10 °C)
Ambient Relative Humidity ±10%
CW = Supplied Chilled Water Temperature ±10 °F (6 °C)
DX = Condenser Coil or Seawater Temperature
±10 °F (6 °C)
Outside Ambient Temperature ±10 °F (6 °C)
Operation
19