Christie GS Series User Manual page 39

Hide thumbs Also See for GS Series:
Table of Contents

Advertisement

Menu item
Description
Service
Displays projector
information, sets test
patterns, error logs, and high
temperature warnings.
GS Series DWU1082-GS User Manual
020-001800-01 Rev. 1 (04-2020)
Copyright ©2020 Christie Digital Systems USA Inc. All rights reserved.
Options
• Projector Info—Displays the current projector settings.
(Read-only)
• Factory Reset—Restores all settings to their default value. It
does not reset network but it resets RS232.
• Test Pattern—Sets the required internal test pattern to
display. To turn off a test pattern, select Off.
• Wheel Index (2X)—Sets the wheel index to Speed 2X. Only
use this setting when a new main board is installed, and the
picture quality needs to be optimized.
• Wheel Index (3X)—Sets the wheel index to Speed 3X. Only
use this setting when a new main board is installed, and the
picture quality needs to be optimized.
• Error Log—Shows the projector error log for debug.
• Mode Adjustment—Fine tunes the horizontal (H) and vertical
(V) start position for a signal in the EDID timing table and
record the values in the system to override the timing table.
To keep the settings, before exiting the menu, select Saved
to Record. To revert to original timing table settings,
manually clear each setting. Factory Defaults do not clear
these override settings.
• Laser Diode Info—Displays the information of each laser
diode bank including its voltage, current, and temperature.
• Fan info— Displays RPM information for fans.
• Light Source Hours— Adjusts the current light source hours
for service.
• ADC Calibration
• Calibration Conditions—Displays the required equipment
for ADC Calibration.
• ADC Calibration—Calibrates RGB Gain or offset for analog
signal only.
• Light Sensor—Performs a calibration. A calibration must be
performed before using in Rental mode or after a laser diode
driver has been replaced.
• Burn in— Burn in starts using the format time on/ time off/
cycle. The items mean time on/time off/ cycle.
• Off
• 60/10/2
• 60/10/4
• 60/10/6
• UST Lens Install—Performs the Ultra Short Throw (UST) lens
installation process.
Operation
39

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dwu1082-gs

Table of Contents