Supervisor Screen
(LRT PD44 Only)
NOTE: This section describes the Supervisor screen for
the LRT PD44 only. See page 34 for the Motor Driven
PD44 Supervisor screen.
Pump Reload
Pump Reload sets a transducer point where the
machine will reload. The point is relative to the rod
stroke mechanical limits.
Reload 3%
Most
Retracted
Position
To change the Pump Reload setting, perform the follow-
ing steps.
1. Press Enter Password button.
2. Enter password.
3. Press the Enter button.
4. Press the Pump Reload Position button.
5. Enter the desired reload position.
6. Press the Enter button.
7. Press the Enter Data button.
313877G
Shot Size Offset -1%
Most
Extended
Position
Shot Size Offset Button
The Shot Size Offset button sets the transducer point
where the metering rods will retract. The factory setting
is -1.
To change the Shot Size Offset setting, perform the fol-
lowing steps.
1. Press Enter Password button.
2. Enter password.
3. Press the Enter button.
4. Press the Shot Size Offset button.
5. Enter the desired Shot Size Offset.
6. Press the Enter button.
7. Press the Enter Data button.
HMI Operation
33