Bosch WORCESTER FR 10 Installation & User's Instructions

Bosch WORCESTER FR 10 Installation & User's Instructions

Intelligent room thermostat

Advertisement

INSTALLATION & USER INSTRUCTIONS
INTELLIGENT ROOM THERMOSTAT
FR 10
FOR USE WITH THE FOLLOWING APPLIANCES:
GREENSTAR CDI COMBINATION BOILERS
GREENSTAR CDI SYSTEM BOILERS FITTED WITH OPTIONAL
INTEGRAL DIVERTER VALVE
GREENSTAR HIGHFLOW CDI COMBINATION BOILERS
very to your door visit MyTub Ltd - www.mytub.co.uk - info@mytub.c

Advertisement

Table of Contents
loading

Summary of Contents for Bosch WORCESTER FR 10

  • Page 1 INSTALLATION & USER INSTRUCTIONS INTELLIGENT ROOM THERMOSTAT FR 10 FOR USE WITH THE FOLLOWING APPLIANCES: GREENSTAR CDI COMBINATION BOILERS GREENSTAR CDI SYSTEM BOILERS FITTED WITH OPTIONAL INTEGRAL DIVERTER VALVE GREENSTAR HIGHFLOW CDI COMBINATION BOILERS very to your door visit MyTub Ltd - www.mytub.co.uk - info@mytub.c...
  • Page 2 The FR 10 offers everything you can expect from a modern heating control: It is both reliable and energy saving. Like all Bosch Group products, the FR 10 has been produced and tested according to the most stringent quality standards so that you can enjoy the Worcester warmth for a long time to come.
  • Page 3: Table Of Contents

    Contents Contents Symbols and safety precautions ....4 Symbols ........4 Safety precautions .
  • Page 4: Symbols And Safety Precautions

    Symbols and safety precautions Symbols and safety precautions Symbols Safety instructions in this document are identified by a warning triangle and are printed on a grey background. Signal words indicate the seriousness of the hazard in terms of the consequences of not following the safety instructions. Caution indicates that minor damage to property could result.
  • Page 5: Safety Precautions

    Symbols and safety precautions Safety precautions B These instructions must be observed to ensure correct opera- tion. B Install and commission the boiler and all accessories in accord- ance with the associated instructions. B Allow only qualified installers to install accessories. B Only use these accessories in conjunction with the heating appliances listed.
  • Page 6: Technical Data For The Accessory Item

    Technical data for the accessory item Technical data for the accessory item The FR 10 can only be connected to a boiler with BUS-enabled Heatronic 3. The FR 10 enables the room temperature control of a single • heating system. The FR 10 must only be used in conjunction with a suitable •...
  • Page 7: Standard Package

    Technical data for the accessory item Standard package Fig. 1 Top section, controller and base for wall mounting Installation and operating instructions Technical data Dimensions 85 mm × 100 mm × 35 mm H × W × D Rated voltage 10 ...
  • Page 8: Supplementary Accessories

    Technical data for the accessory item Supplementary accessories MT 10: Mechanical single channel time switch. • DT 20: Twin channel digital programmer. • Cleaning B If required, use a damp cloth to wipe the controller casing. Never use aggressive or acidic cleaning agents for this. 6 720 617 760 (2008/09) very to your door visit MyTub Ltd - www.mytub.co.uk - info@mytub.c...
  • Page 9: Installation (For Installers Only)

    Installation (for installers only) Installation (for installers only) DANGER: Risk of electric shock B Before installing these accessories: Isolate the voltage supply (230 V AC) to the heat- ing appliance and all additional devices on the bus. Installation The installation location must be suitable for controlling the heat- ing system or heating circuit.
  • Page 10 Installation (for installers only) B Select the installation location. 25 mm 100 mm 0,6 m 1,0 m 85 mm 0,75 m 1,2 m 35 mm 6 720 612 218-02.1J Fig. 2 6 720 617 760 (2008/09) very to your door visit MyTub Ltd - www.mytub.co.uk - info@mytub.c...
  • Page 11 Installation (for installers only) B Remove the top section from the base. 6 720 612 218-04.1R Fig. 3 The mounting surface on the wall should be level. 6 720 617 760 (2008/09) very to your door visit MyTub Ltd - www.mytub.co.uk - info@mytub.c...
  • Page 12 Installation (for installers only) B Fit the base. 3,5 mm 6 mm 6 mm 3,5 mm 6 720 612 218-05.1R Fig. 4 B Connect to the power supply. Heatronic 3 FR 10 ST 19 A F 1 6 720 613 554-01.1R Fig.
  • Page 13: Disposal

    Installation (for installers only) Disposal B Dispose of packaging in an environmentally responsible man- ner. B When replacing components, dispose of the old parts in an environmentally responsible manner. Electrical connections B BUS connection from the controller to other BUS subscribers: Use electrical cable with the minimum specification H05 VV-...
  • Page 14: Commissioning (For Installers Only)

    Commissioning (for installers only) Commissioning (for installers only) 1 Switch on the system. 2 During first commissioning or after a global reset (resetting all adjustments): B Confirm the flashing code 1 HC by pressing 3 System configuration starts automatically, and lasts approxi- mately.
  • Page 15: Operation

    Operation Operation mode Fig. 6 6 720 617 760 (2008/09) very to your door visit MyTub Ltd - www.mytub.co.uk - info@mytub.c...
  • Page 16 Operation Controls Rotary selector - Turn = Adjust value - Press = Confirm setting/value Mode key: - Change operating mode - Accessing user level = hold down for approx. 3 seconds - Accessing installer level = Hold down for approx. 6 seconds - Return to the higher level Symbols Current room temperature or required room temperature...
  • Page 17: Changing The Operating Mode

    Operation Changing the operating mode B Briefly press mode until the required operating mode is dis- played. = constant Comfort = constant Economy = constant Frost The selected operating mode is only enabled if the heating operation is not blocked. Changing the required room temperature Use this function if you want to change the required room temperature by way of an exception, e.g.
  • Page 18: Changing The Standard Setting Of The Required Room Temperature

    Operation Changing the standard setting of the required room temperature Use this function if you want to permanently change the required room temperature away from the standard setting. B Accessing user level: Hold down mode for approx. 3 seconds until – – is displayed. B Release the mode key and turn until the required param- eter is shown:...
  • Page 19: Adjusting The Installer Level (For Installers Only)

    Operation B Briefly press to save the value. B Press mode until the current room temperature is displayed. Adjusting the installer level (for installers only) The installer level is exclusively designed for install- ers. B Accessing installer level: Hold down mode for approx. 6 sec- onds until –...
  • Page 20 Operation 5.4.1 Changing the code (parameter: 5A p) Setting range: 1 to 10 Use this parameter if you want to adjust the code after commis- sioning: B For systems with a single heating circuit: Select code 1. Only one FR 10 can be used per heating system. 5.4.2 Changing the heating circuit configuration (parameter: 5b p) Setting range: 1 to 3...
  • Page 21 Operation 5.4.3 Adjusting the room temperature sensor (parameter: 6A p) Setting range: – 3.0 °C (K) to +3.0 °C (K) Use this parameter if you want to correct the displayed room tem- perature. B Position a precision instrument near FR 10. The precision instrument must not transfer any heat to the FR 10.
  • Page 22 Operation 5.4.5 Selecting amplification factor V (parameter: 6C p) Setting range: 40 % to 100 % Subject to changes in room temperature, the amplification factor V influences the heat demand. B Selecting amplification factor V: – ≤ 50 %: Select a lower factor to reduce the influence on the heat demand.
  • Page 23: Selecting The Heating Program

    Operation Selecting the heating program B Select the heating program with start and stop switching times at the time switch ( time switch operating instructions). Frost protection The heating (circuit pump) starts if the room temperature in the room where the FR 10 is installed falls below 4 °C or the flow temperature falls below 8 °C.
  • Page 24: Troubleshooting

    Troubleshooting Troubleshooting If the boiler has developed a fault, the display will show, for exam- ple, EA. E. Here, EA means a boiler fault; the full stop . means an external fault; E means error (= fault). If the FR 10 has developed a fault, the display will show, for exam- ple, 03 E.
  • Page 25 Troubleshooting Fault Cause Remedy Required room Thermostatic valve(s) are Fully open the thermo- temperature not not opened sufficiently. static valve(s) or ask achieved. your installer to check the valves. Central heating temperature Set the central heating control on the boiler set too temperature controll low.
  • Page 26 Troubleshooting If the fault persists: B Call your installer or customer service and inform them of the fault, quoting the appliance details (from the type plate). Appliance details Type: ......................Part number: ......................Date of manufacture (FD...): ......................6 720 617 760 (2008/09) very to your door visit MyTub Ltd - www.mytub.co.uk - info@mytub.c...
  • Page 27: Tips On Saving Energy

    Tips on saving energy Tips on saving energy Regulate the temperature in adjacent rooms via thermostatic • valves. External heat in the room where th FR 10 is installed (e.g. solar • gain, stove etc.) can result in too little heating in adjacent rooms (the heating system remains cold).
  • Page 28: Environmental Protection

    Environmental protection Environmental protection Environmental protection is a fundamental corporate strategy of the Bosch Group. The quality of our products, their economy and environmental safety are all of equal importance to us and all environmental pro- tection legislation and regulations are strictly observed.
  • Page 29 Notes 6 720 617 760 (2008/09) very to your door visit MyTub Ltd - www.mytub.co.uk - info@mytub.c...
  • Page 30 Notes 6 720 617 760 (2008/09) very to your door visit MyTub Ltd - www.mytub.co.uk - info@mytub.c...
  • Page 31 Notes 6 720 617 760 (2008/09) very to your door visit MyTub Ltd - www.mytub.co.uk - info@mytub.c...
  • Page 32 Dedicated to heating comfort Worcester, Bosch Group Cotswold Way, Warndon, Worcester WR4 9SW Tel. 01905 754624 Fax. 01905 754619 Worcester, Bosch Group is a brand name of Bosch Thermotechnology Ltd. www.worcester-bosch.co.uk very to your door visit MyTub Ltd - www.mytub.co.uk - info@mytub.c...

Table of Contents