Summary of Contents for Bosch BCC100

  • Page 1 Advanced Settings Guide Bosch Connected Control BCC100 Thermostat...
  • Page 2 Advanced Settings Guide Bosch Connected Control BCC100 Thermostat (01.2022)
  • Page 3: Table Of Contents

    1.5.10 Unit Confi guration 1.5.10.1 Compressor Confi guration 1.5.10.2 Auxiliary Heating 1.5.10.3 Humidifi er Control 1.5.10.4 DeHumidifi cation Control 1.5.10.5 Fossil Fuel Fan Control 1.5.10.6 Reversing Valve Energize Method 1.5.10.7 Balance Point 1.5.10.8 Changeover Delay Bosch Connected Control BCC100 Thermostat (01.2022)
  • Page 4: Thermostat Features And Functionality

    On Home screen use +/- to Increase/Decrease the cooling set point. Figure 2 Exit System screen (press ‘x’ in top right corner). On Home screen use +/- to Increase/Decrease the heating set point. Figure 6 Figure 3 Bosch Connected Control BCC100 Thermostat (01.2022)
  • Page 5: Auto Heating/Cooling Set Point

    Location permission is enabled and the thermostat has been registered. Main Menu Weather Select Current Figure 8 Exit System screen (press ‘x’ in top right corner). On Home screen use +/- to change heating and cooling set points. Figure 11 Figure 9 Bosch Connected Control BCC100 Thermostat (01.2022)
  • Page 6: Weather Next 10 Hours

    Main Menu A connection to Wi-Fi is required. Schedule Select a Schedule Main Menu Select “Setup” Weather Select a day Select 5-Days Edit start times Edit heat and cool temps Figure 13 Figure 15 Bosch Connected Control BCC100 Thermostat (01.2022)
  • Page 7: Device Settings

    This feature allows the user to switch the Wi-Fi on and off from the device. The Device Settings are for settings that pertain to the BCC100 device itself. The user can access the device settings by selectiong this section in the menu.
  • Page 8: Brightness

    This feature allows the user to adjust the brightness of the thermostat. Allows the user to set a 4-digit numeric passcode to lock screen. Once set, the BCC100 will prompt user to re-enter password when trying to access touchscreen  Options: High , Medium, Low of thermostat.
  • Page 9: Time Format

    1.4.10 Account Information Provides the user with Account ID, Created Date, and Geo Location. All three fi elds can be changed by clicking the “Change” button. Main Menu Device Settings Device Information Account Figure 25 Bosch Connected Control BCC100 Thermostat (01.2022)
  • Page 10: System Settings

    User can also choose to set a schedule during which the fan will cycle. System Settings If the user chooses no schedule the Fan will continuously cycle. Temperature Unit Figure 28 Figure 30 1 0 | Bosch Connected Control BCC100 Thermostat (01.2022)
  • Page 11: Low Space Temperature Monitor

    This feature allows the user to reset heating or cooling runtime. Selecting "Yes" will reset the respective runtime to Zero and Starting date to the current date. Figure 31 Main Menu System Settings Run Time Reset (Heating or cooling) Figure 33 | 11 Bosch Connected Control BCC100 Thermostat (01.2022)
  • Page 12: Air Filter

    This option is used to update the device with the latest fi rmware version if the automatic update is unsuccessful. Main Menu System Settings System Update Download the most recent update Figure 36 1 2 | Bosch Connected Control BCC100 Thermostat (01.2022)
  • Page 13: Unit Confi Guration

    System Settings Stages Unit Confi guration Heat Type (select Heat Pump) Depending on the Heat type chosen, the options available may vary. Setup Auxiliary Heating (under Heat Type) Figure 37 Figure 38 | 13 Bosch Connected Control BCC100 Thermostat (01.2022)
  • Page 14: Humidifi Er Control

     Default: Dehumidifer Main Menu Main Menu System Settings System Settings Unit Confi guration Unit Confi guration Accessory Accessory Dehumidifi er Select Humidifi er Setup Figure 39 Figure 40 Figure 41 1 4 | Bosch Connected Control BCC100 Thermostat (01.2022)
  • Page 15: Fossil Fuel Fan Control

    Unit Confi guration Select Appliance or Thermostat Heat type (Select Heat Pump) Select Setup Main Menu System Settings Unit Confi guration Heat type (Select Dual Fuel) Select Setup Heat Pump Figure 42 Figure 43 | 15 Bosch Connected Control BCC100 Thermostat (01.2022)
  • Page 16: Balance Point

     Options: 45 sec to 300 sec  Default: 45 sec Main Menu System Settings Figure 46 Unit Confi guration Heat Type (Select Dual Fuel) Heat Pump Select the Changeover Delay box Figure 45 1 6 | Bosch Connected Control BCC100 Thermostat (01.2022)
  • Page 17: Fan On Delay In Cooling

     Default: 300 Seconds Main Menu Advanced Settings Heating & Cooling Enter Professional Access code “1886” Min. Run Time Use the Up and Down keys to select the minimum run time. Figure 47 Figure 48 | 17 Bosch Connected Control BCC100 Thermostat (01.2022)
  • Page 18: Anti Short Cycle (Asc) Timer

     Options: 60 to 300 seconds  Default: 180 seconds Main Menu Advanced Settings Heating & Cooling Enter Professional Access code “1886” Cycle Time Figure 50 1 8 | Bosch Connected Control BCC100 Thermostat (01.2022)
  • Page 19: Second Stage Latching

    Enter Professional Access Code “1886” Enter Action code ”ST” Enter Action code “ST” Latching Select Stage Delay Use the Up and Down keys to select the Stage Delay. Figure 52 Figure 53 | 19 Bosch Connected Control BCC100 Thermostat (01.2022)
  • Page 20: Stage Temp

    This function allows the user to reset the thermostat to initial factory settings. Main Menu Advanced Settings Select Factory Reset Select “Yes” to confi rm Reset or “No” to cancel. Figure 55 2 0 | Bosch Connected Control BCC100 Thermostat (01.2022)
  • Page 21: App Features

    The application connects with Wi-Fi and uses the pin to set the location of your Go to menu thermostat to receive accurate outdoor weather data. Select Schedule Open app Add Schedule Go to menu Select Location Figure 57 Figure 56 | 21 Bosch Connected Control BCC100 Thermostat (01.2022)
  • Page 22: Device Log

    This function allows user to select the time period and function to view device history.  Options: Adjustments, Operation mode, Device Alerts , General, others  Default: Adjustment Open app Go to menu Select Device log Figure 58 2 2 | Bosch Connected Control BCC100 Thermostat (01.2022)
  • Page 23: Staging Logic

    4 WSHP Fault Codes Staging response determines how the thermostat stages heating or cooling calls If your Bosch Connected Control (BCC) thermostat is connected to one of Bosch’s based on the diff erence between space temperature and the set point (1.0°F or Water Source Heat Pump (WSHP) products, the following WSHP fault codes can 1.5°F).
  • Page 24: Action Codes

    Use the Up and Down keys to select sensor calibration Installer Access Enter professional access code “1886” Enter action code “HSD” Use the Up and Down keys to select relative humidity hysteresis Figure 62 Figure 60 2 4 | Bosch Connected Control BCC100 Thermostat (01.2022)
  • Page 25: Sensitivity Level (Ss)

    5.6 Staging (ST) Ability to confi gure staging settings for Latching, Stage Delay, and Stage Temp. Main Menu Advanced Settings Installer Access Enter professional access code “1886” Enter action code “ST” Figure 64 | 25 Bosch Connected Control BCC100 Thermostat (01.2022)
  • Page 26 Advanced Settings Guide NOTES: 2 6 | Bosch Connected Control BCC100 Thermostat (01.2022)
  • Page 27 Advanced Settings Guide NOTES: | 27 Bosch Connected Control BCC100 Thermostat (01.2022)
  • Page 28 United States and Canada Bosch Thermotechnology Corp. 65 Grove St. Watertown, MA 02472 Tel: 866-642-3198 Fax: 603-965-7581 www.bosch-thermotechnology.us BTC 469302103 A / 01.2022 Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances.

Table of Contents