Table of Contents

Advertisement

Another glass gasket (A) is located between the door and the glass. The gasket is stuck on the
exterior surface of the door (B). Install according to the following illustrations.
Location
Length
Behind the door
235 cm

6.3 Door

In order for the wood fire to burn at its best efficiency, the door must provide a perfect seal with
the firebox. The tightness of the door seal can be verified by closing and latching the door on
a strip of paper. The test must be performed all around the door. If the paper slips out easily
anywhere, Either adjust the door or replace the gasket.
Figure 25: Door gasket seal verification
6.3.1 Adjustment
The gasket seal may be improved with a simple latch mechanism adjustment to increase or
reduce the pressure on the gasket:
Page 26
A
5/8"
16mm
B
3/4"
19mm
Figure 24: Replacing the glass gasket
Dimension
Flat 25 mm
3/4"
19mm